background image

LIMITATIONS

 

OF

 

USE

TT

 

Series

 

LR Manual

 

Page

 

01

 

 

TT

 

Series

 

instruments

 

are

 

intended

 

for

 

measurement

 

of

 

low

 

differential

 

air

 

pressure

 

in

 

and

 

around

 

commercial

 

and

 

industrial

 

air

 

handling

 

systems,

 

and

 

for

 

use

 

with

 

a

 

Pitot

 

Static

 

Tube.

   

 

The

 

instruments

 

are

 

not

 

suitable

 

for

 

liquid

 

pressure

 

measurement,

 

and

 

must

 

not

 

be

 

used

 

with

 

corrosive,

 

toxic

 

or

 

otherwise

 

hazardous

 

gases.

   

 

The

 

instruments

 

are

 

not

 

classified

 

“Flameproof”

 

or

 

“Intrinsically

 

Safe”

 

and

 

consequently

 

must

 

not

 

be

 

used

 

where

 

an

 

explosion

 

hazard

 

may

 

exist

 

and

 

are

 

not

 

authorised

 

for

 

Life

 

Support

 

applications.

 

 

During

 

normal

 

operation

 

small

 

quantities

 

of

 

air

 

(typically

 

less

 

than

 

0.1ml/min)

 

may

 

pass

 

into

 

or

 

out

 

of

 

the

 

system

 

under

 

test:

 

it

 

is

 

the

 

user’s

 

responsibility

 

to

 

consider

 

the

 

consequences

 

of

 

such

 

leakage

 

before

 

determining

 

the

 

suitability

 

of

 

the

 

instrument

 

for

 

any

 

particular

 

purpose.

 

 

The

 

instrument

 

must

 

be

 

turned

 

off

 

before

 

it

 

is

 

stored

 

or

 

transported

 

and

 

if

 

it

 

is

 

to

 

be

 

stored

 

for

 

a

 

long

 

period

 

of

 

time

 

or

 

is

 

to

 

be

 

transported

 

by

 

air,

 

the

 

battery

 

must

 

be

 

removed.

 

 

There

 

is

 

a

 

12

month

 

guarantee

 

on

 

all

 

manufactured

 

parts.

  

This

 

guarantee

 

does

 

not

 

cover

 

any

 

consumables,

 

and

 

/or

 

wear

 

and

 

tear

 

during

 

normal

 

or

 

abnormal

 

use.

 

 

The

 

guarantee

 

becomes

 

null

 

and

 

void

 

if

 

the

 

instruments

 

parts

 

have

 

been

 

tampered

 

with,

 

misused,

 

abused

 

or

 

used

 

outside

 

the

 

parameters

 

set

 

out

 

in

 

the

 

manual.

 

 

The

 

manufacturer

 

will

 

determine

 

if

 

the

 

instrument

 

is

 

repairable

 

or

 

requires

 

replacement;

 

charges

 

may

 

apply.

 

 

Содержание TT 570 A

Страница 1: ...OPTERATING MANUAL TT Series Micromanometer 570 Low Resolution...

Страница 2: ...mitations of Use 01 Keypad Controls 02 Mode of Operation 03 Display 04 Pressure Connections 04 User Menu 05 07 Option Menu 08 10 Conversion Tables 11 Duct Traverse Points 12 Downloading Data 13 Mainte...

Страница 3: ...less than 0 1ml min may pass into or out of the system under test it is the user s responsibility to consider the consequences of such leakage before determining the suitability of the instrument for...

Страница 4: ...low2 10 sec Slow3 15 sec Slow4 20 sec UNITS Changes the unit of measurement The units are arranged in loop formation as follows model dependent Kpa mmH2O inH2O mbar m sec ft min Kpa STORE Stores readi...

Страница 5: ...ge the internal battery with the charger supplied Units The unit of measurement is shown on the right hand side of the display Being an auto ranging instrument the correct resolution and the decimal p...

Страница 6: ...es Connect upstream tapping to Signal In and downstream tapping to Reference Pressure readings should always be positive Flow Grids Connect Ve tapping to Signal In and Ve tapping to Reference Pressure...

Страница 7: ...ia the Hyper terminal Note DP Measurement no longer supply thermal printers Back Light Period To alter the backlight time Use y and z to switch on the back light Temp Pressure To change the air stream...

Страница 8: ...Setting 3600 RS 232 Result Period Min Setting 0005 Back Light Period Press ENTER To switch off input 0000 Temp Pressure User Menu Select Date Format Exit Set Clock Back Light Period Auto Zero Time 015...

Страница 9: ...lect Use y and z to set each digit or value then press ENTER Set Clock Date Format Auto Zero Time DD MM YY Switch Off Period MM DD YY RS 232 Result Period Exit Back Light Period Select Temp Units Temp...

Страница 10: ...mal printer Page 10 PC Connection To download stored data to a PC See Downloading Data page 13 Selecting from a list Entering a value Use y and z to scroll Press ENTER to select Use y and z to set eac...

Страница 11: ...Setting 50 C Exit 850 mbar Option Menu Before data logging select the correct unit in measurement mode Review Results Record Option Del Last Result Record every Clear Memory 00 Min 10 Sec Set Temp Pre...

Страница 12: ...mupload icon A window will appear on screen select the comm port and click the Upload option Another window will appear on screen Give the file a name choose which folder to save it in and then press...

Страница 13: ...c 999 97 0 2777 1 0 4719 cfm 2118 88 0 5885 2 1189 1 Velocity m sec ft min m sec 1 0 005 ft min 196 85 1 Air Velocity Calculations using S I Scales For non standard air conditions V 1 291 x PT 1013 25...

Страница 14: ...nnected to the Reference port Log Linear Rule for Traverse Points on 3 Diameters in a Circular Duct Ideally traverse points should be at least six duct diameters away from any bend or obstruction in t...

Страница 15: ...creen When the data is downloaded the message Records received successfully will appear click OK Close the downloading software and open the file using Notepad MAINTENANCE CALIBRATION TT Series LR Man...

Страница 16: ...cal Output Socket RS 232 baud rate 9600 Data Logging Up to 2500 any units Software Download data to PC in very basic form Power Source Dry cell MN1604 PP3 or Rechargeable System Air Leak 0 1 ml minute...

Отзывы: