DPM PosiTector Скачать руководство пользователя страница 4

4

- Bluetooth Pairing info is cleared.

-  Alarm values are set to default.

- Menu settings are returned to the following:

NOTE:

- Date and Time are not affected by either 

Reset

.

Units

= Celsius

Flip Display

= Normal

Auto Sync 

= OFF

Alarms

= OFF

Alarm Sound

= OFF

Wet Bulb

= OFF

White on Black

= OFF 

Language

= English

Battery Type

= Alkaline

Backlight

= Normal

Auto Log Interval

= 5 min

Bluetooth Streaming

= OFF

USB Drive

= ON

Wet Bulb

When selected, the wet bulb temperature (Tw) is displayed on the
main screen. It is calculated from Ta and RH using an air pressure
of 1.0 atmospheres (1013 mbar). Variations of Tw at other
pressures could be greater than ±1°C (±2°F).

This menu item only appears when all memory functions

are turned off. Wet Bulb readings cannot be stored in memory. 

NOTE:

(Advanced models only)

Displays a real-time graph of the readings over
the last three minutes. Use Trend Charts to
monitor short-term environmental changes and
spot trends. 

Press the 

Up

button to scroll through

the trend charts

Trend charts can only be displayed

when memory is off.

Trend Chart

Shortcut:

(Advanced models only)

NOTE:

Battery Type

Selects the type of batteries used in the instrument from a choice
of “Alkaline”, “Lithium” or “NiMH” (Nickel-metal hydride
rechargeable). If NiMH is selected, the instrument will trickle
charge the batteries while connected via USB to a PC or optional
AC charger. The battery state indicator icon is calibrated for the 

Содержание PosiTector

Страница 1: ...PosiTector DPM Quick Guide v 3 1 Dew Point Meter...

Страница 2: ...sured Ts Surface Temperature measured Td Dew Point calculated Ts Td Surface minus Dew Point Temperature calculated Tw Wet Bulb Temperature calculated Advanced Models Only The PosiTector DPM powers up...

Страница 3: ...Bluetooth OFF Trend Chart None Perform a more thorough Hard Reset by powering down the instrument waiting several seconds then simultaneously holding both the center and buttons until the Reset symbol...

Страница 4: ...uld be greater than 1 C 2 F This menu item only appears when all memory functions are turned off Wet Bulb readings cannot be stored in memory NOTE Advanced models only Displays a real time graph of th...

Страница 5: ...r dimming Advanced only Memory Management Memory Management Memory The PosiTector DPM can record datasets in memory for printing to the optional Bluetooth wireless printer transferring to a computer o...

Страница 6: ...the instrument will wake up take a reading sync to PosiTector net if configured and power down The instrument can record approximately 8 000 datasets while in this mode using fresh alkaline batteries...

Страница 7: ...connected USB or Bluetooth to an internet connected PC running PosiTector Desktop Manager PDM Sync Now Connect Connect Menu Connect Menu The PosiTector uses a USB mass storage device class which provi...

Страница 8: ...umidity sensors Keep fingers away from the sensor as body heat can cause incorrect readings Allow time for the instrument to acclimate and for the readings to stabilize when moving the instrument betw...

Страница 9: ...1 F Air Temperature 40 to 80 C 40 to 175 F 0 5 C 1 F 0 1 C 0 1 F Humidity 0 to 100 3 0 1 Operating Range 40 C to 80 C 40 F to 175 F www defelsko com DeFelsko Corporation USA 2011 All Rights Reserved T...

Отзывы: