35
7.3.
Maintenance and test intervals
Description
After
use
Every
month
Every
years
Every
6
years
Complete
Equipment
Clean and disinfect as
necessary
x
Visual inspection
x
Charge cylinder to correct
pressure
x
Function
test
as
per
instruction included in the
maintenance kit.
x
Spray the antifogging liquid
on the internal surface of
the hood visor
x
Sealing
elements,
and
damaged
or
worn
components substitution
X
Cylinder
Check test date on cylinder
x
Re-certification
–
Pressure
test according to national
standards
DPI, while endeavoring to ensure correctness of statements of fact and advice
contained in this publication, gives no guarantee or warranty in respect thereof, and
accepts no liability for any mis-statement or inaccuracy in publication, or for any
omission therefrom.
8.
Transportation and storage
Sekur Navy Cap, both 10 and 15 minutes
, equipment “ready for use” should be:
-
Transported and stored in their original packaging when new or not yet used;
-
protected from dust and dirt, physical and mechanical damage and direct sunlight
during transportation and storage;
-
transported and stored in a mild temperature and dry environment.