Doyson S 10 FM Скачать руководство пользователя страница 2

MAINS 230 Vca.

2x0,75 mm.

STEREO

ZONE

CABLE REF. W-2

MINIMUM SECTION

2X0.50 MM

Speaker

Ref. SP 5

Speaker

Ref. SP 5

STEREO

ZONE

CABLE REF. W-2

MINIMUM SECTION

2X0.50 MM

MAINS

100-240 Vca.

0

5

8

9

M

-

+

+

-

ANT

C1L

C1R

CABLE REF.  W-8

MINIMUM SECTION

2X1MM

6X0,25 MM

R+ R- L- L+

0 5 8 9 M

C1L C1R

S 10 FM BT

UC 100 S

0

5

-

+

+

-

R+ R- L- L+

0 5 8 9

C1L C1R

S 10 FM BT

M

WIRING DIAGRAM FOR S 10 FM BT CONTROL 
MODULE AND UC 100 S CENTRAL UNIT

System with power supply unit

System with central unit

FA 12 BI

Power supply

unit

For AUXILIARY CONNECTION of audio, TV, PC, etc. please 
use 0 (ground) and C1L and C1R (Left and right channel 1)

ANTENNA CONNECTION:

 Conductor wire of 80 cm. In zones of 

bad reception, connection to outdoor antenna it is highly recommended.

NOTE.- The

  

UC 100 S

 

 

supports a máximum of 10 sound control modules and a maximum distance of 100 mts.of cable to the last element to 

be controlled. For higher installations, power supply units or a more powerful central unit would be required.
Connect the ‘M’ in case of mixed systens where units with call function have been installed (control modules with microphone or CN500 microphone desk)

SYSTEM PROGRAMMING

Once all the system units are already installed, a zone number must be assigned to each control module as follows:
1st.- Keep the keys 

< >

 pressed during 4 seconds. The leds of every control module will be flashing at this point. 

2nd.- Choose the control module you want to be the “zone 1” and press the on/off key.  The number “1” will be memorized as a zone number in 
that control module. 
3rd.- Now the rest of control modules will show the leds flashing. Choose again which control module you want to be the “zone 2” and press the 
on/off key of that module. Repeat the process as many times as control modules/zones are in the installation.
4th- Once the zone assignment is finished, keep the control module on/off key pressed during 2 or 3 seconds in order to leave the “assingnment 
zone mode”.

0
5
8
9

C1 R

C1 L

GROUND - Vcc
POWER SUPPLY 12 +Vcc
COMMUNICATIONS
COMMUNICATIONS
RIGHT CHANNEL 1 
LEFT CHANNEL 1

=
=
=
=
=
=

Отзывы: