TROUBLESHOOTING
BEFORE CALLING FOR SERVICE
ANSWERS TO MOST FREQUENT QUESTIONS
Always cut off the main power before replacing any parts.
Control parts on the front:
To remove parts from front panels, you have to
go on the side of the unit.
Questions
Solutions
The unit does not turn on when installed.
Check if the main switch is on.
Check the breaker of the building and on the unit.
Check the electric cable of the unit is connected.
The blower runs but the unit does not produce
heat.
Make sure that the thermostat is adjusted to the
desired temperature (over ambient temperature)
and the pilot light will go on.
Check the heating element and its connection.
The blower runs but the unit does not produce
steam.
Check the water level in the pan.
Adjust the humidity control at 4 1/2, the pilot
light of the humidity control should came on and
the water element should run at full capacity.
Check if the immersion element connection is
OK.
Clean the water pan and the immersion element.