March 2005

1  Installation

Out

1/2 Male

IN

3/8 Female

24Vac - 50/60Hz

(DAF001V3)

The set 

o

+

p

 is supplied together with the water meter.

You must always use the filter 

p

 

or small particles will damage the meter and your

dough will be dirty and unusable.
To connect the filter to the inlet and additional pipes to the outlet you must grab with an
appropriate tool the fixing parts 

n

, so that internal pipes do no move causing water

leaks. 

If you need to open the meter (voiding the warranty) you should fully unscrew 

r

 

and

partially 

q

, twirling the box cover over its left vertical axle, otherwise internal cables

can be broken. 
Do not hang the meter by the electrical cables or by the pipes. Appropriate fixing
accessories are supplied to fix the meter in the wall. First fix the meter on a perfectly
vertical wall as in the picture and then connect power and water pipes. If the meter is
not fixed vertically the accuracy of the metering device will decrease.

24 Vac/dc,  50/60

Содержание DAF001V3

Страница 1: ...March 2005 Installing and Using Water Meter DOYON DAF001V3 Release V2 0...

Страница 2: ...at internal pipes do no move causing water leaks If you need to open the meter voiding the warranty you should fully unscrew r and partially q twirling the box cover over its left vertical axle otherw...

Страница 3: ...March 2005 2 Using the water meter 6 7 8 9 2 1 Description of the electronic controls 1 Dosing ON valve open 2 Start stop dosing...

Страница 4: ...March 2005 3 Water quantity preset 4 Increase water quantity preset 5 Decrease water quantity preset 6 Power on off 7 Water temperature C or F 8 Quantity since last reset 9 Water quantity reset...

Страница 5: ...water is done indicator n goes off and the valve is switched off You will have now Total and Preset displays equal To start a new dose of the same quantity just press key No need to press key If you...

Страница 6: ...from 32 F to 214 F Water metering from 0 1 to 99 9 litres US Gal Can Gal in steps of 0 1 Accuracy 2 with water flow rates from 2l min to 25l min o From 0 5 to 6 5 US Gal min o From 0 4 to 5 5 Can Gal...

Страница 7: ...ON PLEASE CONTACT OUR OFFICE DOYON EQUIPMENT INC 1255 rue Principale Lini re Qc Canada G0M 1J0 Tel 1 418 685 3431 Canada 1 800 463 1636 U S 1 800 463 4273 FAX 1 418 685 3948 Internet http www doyon qc...

Страница 8: ...onsible for having the equipment properly installed operated under normal conditions with proper supervision and to perform periodic preventive maintenance If any parts are proven defective during the...

Отзывы: