Attach the limit plates to either end
of the rack. Set them so they touch
the limit-switch on the motor
before the gate reaches the end of
its travel. Note the gate will slide for
about another 2-3 cm after the limit
switch stops.
Depending on whether the motor
is on the right or the left, adjust the
jumper (next to the yellow button)
selecting the direction of the “Open”
manoeuvre as shown
Plug in the motor and switch on the
power.
Press the P2 button for 4 seconds
until LED flashes. Wait for ‘click’
sound.
Press the Yellow button. The gate
should open to the fully
Press the yellow button again. The
gate should close completely.
The gate is now ready to operate.
SETTING GATE LIMITS
2.
1.
3.
4.
5.
6.
The P1 button is used for programming additional remote controls. See ‘Connect a Remote’ on
easygate.com.au
The P2 button is used to toggle on/off the faster gate movement.
•
Light on = fast mode.
•
Flashing light = connected devices are not calibrated. Press the button for 5 seconds.
The P3 button is auto-close function.
•
Light on = gate will auto-close after 20 seconds
•
Light off = gate stays open until given a close command.
BASIC SETTINGS
P1 BUTTON
P2 BUTTON
P3 BUTTON
YELLOW
BUTTON
Watch install
videos at
easygate.com.au