iPack C3.3 Lithium Iron Phosphate Battery
Residential Energy Storage System
User Manual
Date: 2021-03-18
5
Detect the voltage and temperature of cell, the voltage and current of battery.
•
SOC estimate:
Indicate the precise volume of remaining electricity.
•
Alarm:
Alarm when overvoltage, under voltage, overcurrent, over temperature or under temperature occurs.
•
Protection:
Protect against over voltage, under voltage, over current, over temperature, under temperature, cell fault
and hardware failure.
•
Report:
Report alarm messages and operation data to PCS via CAN network ports.
•
Parallel connection:
Support a maximum of 6 batteries in parallel connection.
•
Power-off triggered by fault:
%DWWHU\SRZHUVRႇLIOHYHOWKUHHXQGHUYROWDJH9FHOORUSDUDOOHOFRQQHFWLRQIDLOXUHKDSSHQV
•
Forced power-off:
When battery does not connect to mains supply, hold POWER button for two seconds and battery powers
Rႇ
•
Activation:
,QSXW9a9YLD33WHUPLQDOVEDWWHU\ZLOOEHDFWLYDWHGIURPRႇPRGHWRVWDQGE\VWDWXV
2.3 Appearance and Terminals
The battery is an energy storage unit composed of cells, mechanical parts, battery management system (BMS)
as well as power and signal terminals.
Table 2-1
Mechanical features
Parameter
Value
Dimension
W445*D131*H399.6 mm
Weight
Around 29kg
Installation
Rack-mounted installation or Wall-mounted bracket installation
445
399.6
131
3 4 5
1
2
6
7
8