Dover Wilden Saniflo PV15 LSH Скачать руководство пользователя страница 13

TT4276 EOM-P8/PV8M 5/04   TT4267 5/04

 

11 

WILDEN PUMP & ENGINEERING, LLC

PV15 SANIFLO™ LSH

TEFLON

®

-FITTED

  

Height ................................. 864 mm (34.0")

Width .................................. 638 mm (25.1")

Depth .................................. 368 mm (14.5")

Est. Ship Weight .......................71 (156 lbs.)

Air Inlet ....................................19 mm (3/4")

Inlet  .........................................76 mm (3.0")

Outlet,  .....................................76 mm (3.0")

Suction Lift ....................... 4.7 m Dry (15.4')

   

9.0 m Wet (29.5')

Displacement/Stroke .......... 1.82 L (.48 gal.)

Max. Flow Rate ............ 532 lpm (141 gpm)

Max. Size Solids (compressible)

          Mushroom Valve .......... 7.9 mm (0.3")

          Ball Valve ................... 12.7 mm (0.5")

          Flap Valve .......................76 mm (3.0")

1

Displacement per stroke was calculated at 

4.8 bar (70 psig) air inlet pressure against a 
2 bar (30 psig) head pressure.

Example: 

To pump 265 lpm (70 gpm) 

against a discharge pressure head of 2.8 
bar (40 psig) requires 5.0 bar (73 psig) and 
110 Nm

3

/h (65 scfm) air consumption.

Caution: Do not exceed 8.6 bar (125 psig) 
air supply pressure.

Flow rates indicated on chart were determined by pumping water with a vertically 
mounted, side ported ball check confi guration. When alternate check valve options are 
used, multiply fl ow rate by appropriate factor. Mushroom check valve = 86%. For optimum 
life and performance, pumps should be specifi ed so that daily operation parameters will 
fall in the center of the pump performance curve.

PV15 SANIFLO™ LSH

ULTRA-FLEX

-FITTED

  

Height ................................. 864 mm (34.0")

Width .................................. 638 mm (25.1")

Depth .................................. 368 mm (14.5")

Est. Ship Weight .......................71 (156 lbs.)

Air Inlet ....................................19 mm (3/4")

Inlet  .........................................76 mm (3.0")

Outlet,  .....................................76 mm (3.0")

Suction Lift ....................... 4.5 m Dry (14.8')

   

9.3 m Wet (30.6')

Displacement/Stroke ......... 2.00 L (.53 gal.)

Max. Flow Rate ............ 594 lpm (157 gpm)

Max. Size Solids (compressible)

          Mushroom Valve .......... 7.9 mm (0.3")

          Ball Valve ................... 12.7 mm (0.5")

          Flap Valve .......................76 mm (3.0")

1

Displacement per stroke was calculated at 

4.8 bar (70 psig) air inlet pressure against a 
2 bar (30 psig) head pressure.

Example: 

To pump 265 lpm (70 gpm) 

against a discharge pressure head of 2.8 
bar (40 psig) requires 4.4 bar (64 psig) and 
97 Nm

3

/h (57 scfm) air consumption.

Caution: Do not exceed 8.6 bar (125 psig) 
air supply pressure.

Flow rates indicated on chart were determined by pumping water with a vertically 
mounted, side ported ball check confi guration. When alternate check valve options are 
used, multiply fl ow rate by appropriate factor. Mushroom check valve = 93%. For optimum 
life and performance, pumps should be specifi ed so that daily operation parameters will 
fall in the center of the pump performance curve.

P E R F O R M A N C E

GPM

[LPM]

(25) 

[42]

(50) 

[85]

(75) 

[127]

(100) 

[170]

120

100

80

60

40

20

0

8

7

6

5

4

3

2

1

0

300

275

250

225

200

175

150

125

100

75

50

25

0

AIR CONSUMPTION

(SCFM)

 

[Nm

3

/h]

  20 40 60 80 100 120 

140 160 180

 

[76]  [151] [227] [303] [379] [454] [530] [606] [681]

GPM

[LPM]

(25) 

[42]

(50) 

[85]

(75) 

[127]

(100) 

[170]

120

100

80

60

40

20

0

8

7

6

5

4

3

2

1

0

300

275

250

225

200

175

150

125

100

75

50

25

0

AIR CONSUMPTION

(SCFM)

 

[Nm

3

/h]

  20 40 60 80 100 120 

140 160 180

 

[76]  [151] [227] [303] [379] [454] [530] [606] [681]

Содержание Wilden Saniflo PV15 LSH

Страница 1: ...EOM R e f i n e y o u r p r o c e s s Engineering Operation Maintenance Saniflo Series METAL Pumps PV8 PV15 LSH TT4454 TT4267 EOM PV8 PV15M LSH 10 04 ...

Страница 2: ...ance Curves Rubber Fitted 10 TPE Fitted 10 Teflon Fitted 11 Ultra Flex Fitted 11 B Suction Lift Curves 12 SECTION 6 SUGGESTED INSTALLATION OPERATION TROUBLESHOOTING 13 SECTION 7 ASSEMBLY DISASSEMBLY 16 SECTION 8 EXPLODED VIEW PARTS LISTING PV8 Vertically Mounted Side Ported Manifold 24 PV15 Horizontally Mounted No Manifold 26 PV15 Vertically Mounted Center Ported Manifolds 28 PV15 Vertically Mount...

Страница 3: ...components Consult Chemical Resistance Guide E4 CAUTION Do not exceed 82 C 180 F air inlet temperature for Pro Flo V models CAUTION Pumps should be thoroughly flushed before installing into process lines FDA and USDA approved pumps should be cleaned and or sanitized before being used CAUTION Always wear safety glasses when operating pump If diaphragm rupture occurs material being pumped may be for...

Страница 4: ...D ALUMINUM AIR VALVE N NICKEL PLATED ALUMINUM DIAPHRAGMS FB FDA BUNA N 2 Red Dots FE FDA NORDEL 2 Blue Dots FG SANIFLEX Hytrel Cream FW FDA WIL FLEX Santoprene Off white Dot TF TEFLON PTFE White UB ULTRA FLEX BUNA N Red Dot UE ULTRA FLEX NORDEL Blue Dot CHECK VALVES FB FDA BUNA N BALL FE FDA NORDEL BALL FG SANIFLEX BALL FV FDA VITON BALL FW FDA WIL FLEX Santoprene BALL TF TEFLON PTFE BALL TM TEFLO...

Страница 5: ...pump These same hydraulic forces lift the discharge valve ball off its seat while the opposite discharge valve ball is forced onto its seat forcing fluid to flow through the pump discharge The movement of diaphragm A toward the center of the pump creates a vacuum within liquid chamber A Atmos pheric pressure forces fluid into the inlet manifold of the pump The inlet valve ball is forced off its se...

Страница 6: ...ARD inch A 625 24 6 B 318 12 5 C 231 9 1 D 518 20 4 E 767 30 2 F 800 31 5 G 368 14 5 H 520 20 5 J 401 15 8 K 351 13 8 L 318 12 5 M 356 14 0 N 10 0 4 P 48 1 9 PV8 Saniflo LSH Vertically Mounted Side Ported With Flap Valve ITEM METRIC mm STANDARD inch A 625 24 6 B 318 12 5 C 201 7 9 D 518 20 4 E 800 31 5 F 831 32 7 G 368 14 5 H 520 20 5 J 401 15 8 K 351 13 8 L 318 12 5 M 356 14 0 N 10 0 4 P 48 1 9 M...

Страница 7: ... 6 E 861 33 9 F 97 3 8 G 520 20 5 H 368 14 5 J 401 15 8 K 351 13 8 L 318 12 5 M 356 14 0 N 10 0 4 P 48 1 9 PV15 Saniflo LSH Vertically Mounted Center Ported With Flap Valve Shown ITEM METRIC mm STANDARD inch A 640 25 2 B 102 4 0 C 518 20 4 D 894 35 2 E 940 37 0 F 97 3 8 G 520 20 5 H 368 14 5 J 401 15 8 K 351 13 8 L 318 12 5 M 356 14 0 N 10 0 4 P 48 1 9 D I M E N S I O N A L D R A W I N G S MM 04 2...

Страница 8: ... 5 J 401 15 8 K 351 13 8 L 318 12 5 M 356 14 0 N 10 0 4 P 48 1 9 PV15 Saniflo LSH Vertically Mounted Side Ported With Flap Valve Shown ITEM METRIC mm STANDARD inch A 640 25 2 B 325 12 8 C 102 4 0 D 518 20 4 E 892 35 1 F 953 37 5 G 368 14 5 H 520 20 5 J 401 15 8 K 351 13 8 L 318 12 5 M 356 14 0 N 10 0 4 P 48 1 9 D I M E N S I O N A L D R A W I N G S B F G P H E D C B A J K N L M 19 mm 3 4 FNPT AIR ...

Страница 9: ...G S DIMENSIONS PV15 Saniflo LSH Horizontal Mounted With Flap Valve ITEM METRIC mm STANDARD inch A 452 17 8 B 226 8 9 C 518 20 4 D 650 25 6 E 632 24 9 F 493 19 4 G 267 10 5 H 536 21 1 J 508 20 0 K 521 20 5 L 401 15 8 M 351 13 8 N 318 12 5 P 356 14 0 R 10 0 4 S 48 1 9 MM 42 0 4 MM 04 2 8 534 MM 42 0 3 2 MM 04 2 4 3 2 0 ...

Страница 10: ...Air Inlet 19 mm 3 4 Inlet 51 mm 2 0 Outlet 51 mm 2 0 Suction Lift 6 2 m Dry 20 4 9 3 m Wet 30 6 Displacement Stroke 2 99 L 79 gal Max Flow Rate 582 lpm 154 gpm Max Size Solids compressible Mushroom Valve 7 9 mm 0 3 Ball Valve 12 7 mm 0 5 Flap Valve 51 mm 2 0 1 Displacement per stroke was calculated at 4 8 bar 70 psig air inlet pressure against a 2 bar 30 psig head pressure Example To pump 265 lpm ...

Страница 11: ...ip Weight 67 Kg 147 lbs Air Inlet 19 mm 3 4 Inlet 51 mm 2 0 Outlet 51 mm 2 0 Suction Lift 5 2 m Dry 17 0 9 3 m Wet 30 6 Displacement Stroke 2 00 L 53 gal Max Flow Rate 541 lpm 143 gpm Max Size Solids compressible Mushroom Valve 7 9 mm 0 3 Ball Valve 12 7 mm 0 5 Flap Valve 51 mm 2 0 1 Displacement per stroke was calculated at 4 8 bar 70 psig air inlet pressure against a 2 bar 30 psig head pressure ...

Страница 12: ... 156 lbs Air Inlet 19 mm 3 4 Inlet 76 mm 3 0 Outlet 76 mm 3 0 Suction Lift 5 2 m Dry 17 0 9 3 m Wet 30 6 Displacement Stroke 2 95 L 78 gal Max Flow Rate 624 lpm 165 gpm Max Size Solids compressible Mushroom Valve 7 9 mm 0 3 Ball Valve 12 7 mm 0 5 Flap Valve 76 mm 3 0 1 Displacement per stroke was calculated at 4 8 bar 70 psig air inlet pressure against a 2 bar 30 psig head pressure Example To pump...

Страница 13: ...Ship Weight 71 156 lbs Air Inlet 19 mm 3 4 Inlet 76 mm 3 0 Outlet 76 mm 3 0 Suction Lift 4 5 m Dry 14 8 9 3 m Wet 30 6 Displacement Stroke 2 00 L 53 gal Max Flow Rate 594 lpm 157 gpm Max Size Solids compressible Mushroom Valve 7 9 mm 0 3 Ball Valve 12 7 mm 0 5 Flap Valve 76 mm 3 0 1 Displacement per stroke was calculated at 4 8 bar 70 psig air inlet pressure against a 2 bar 30 psig head pressure E...

Страница 14: ...V8 SANIFLO LSH SUCTION LIFT CAPABILITY PV15 SANIFLO LSH SUCTION LIFT CAPABILITY S e c t i o n 5 B S U C T I O N L I F T C U R V E S PSIG BAR Dry Vacuum Inlet Air Pressure METER FT H20 TPE Diaphragms Traditional Rubber Diaphragms Ultra Flex Diaphragms Teflon Diaphragms 26 24 22 20 18 16 14 12 10 8 6 4 2 0 7 6 5 4 3 2 1 0 0 10 20 30 40 50 60 70 80 90 100 0 7 1 4 2 0 2 7 3 4 4 1 4 8 5 5 6 2 6 9 PSIG ...

Страница 15: ...d off which improves pump performance MUFFLER Sound levels are reduced below OSHA specifications using the standard Wilden muffler Other mufflers can be used to further reduce sound levels but they usually reduce pump performance ELEVATION Selecting a site that is well within the pump s dynamic lift capability will assure that loss of prime issues will be eliminated In addition pump efficiency can...

Страница 16: ...F VALVE S U G G E S T E D I N S T A L L A T I O N NOTE In the event of a power failure the shut off valve should be closed if restarting of the pump is not desirable once power is regained AIR OPERATED PUMPS To stop the pump from operating in an emergency situation simply close the shut off valve user supplied installed in the air supply line A properly functioning valve will stop the air supply t...

Страница 17: ... it possible to identify pumps that are poorly suited to their applications Pump will not run or runs slowly 1 Ensure that the air inlet pressure is at least 0 4 bar 5 psig above startup pressure and that the differential pressure the difference between air inlet and liquid discharge pressures is not less than 0 7 bar 10 psig 2 Check air inlet filter for debris see recommended installation 3 Check...

Страница 18: ...side down and allowing any fluid to flow into a suitable container Be aware of any hazardous effects of contact with your process fluid NOTE The model photographed for these instructions incorporates Teflon diaphragms Step 1 Prior to disassembly alignment marks should be placed on the liquid chambers and air chambers to assist with proper alignment during reassembly Step 2 Loosen the wing nut and ...

Страница 19: ... both sides of the pump remove the upper flap from the flap valve housing Repeat process for the inlet valve assemblies as well Inspect parts for nicks gouges chemical attack or abrasive wear Step 5 On both sides of the pump remove the remaining clamp bands valve housing and gaskets Inspect parts for nicks gouges chemical attack or abrasive wear Note To ensure proper alignment during reassembly of...

Страница 20: ...e directions loosen and remove one of the two outer pistons diaphragm assemblies Step 10 After loosening and removing one outer piston diaphragm assembly can be removed from the center section Step 11 To remove the remaining diaphragm assembly from the shaft secure shaft with soft jaws a vise fitted with plywood or other suitable material to ensure shaft is not nicked scratched or gouges Using an ...

Страница 21: ... process fluid The Wilden PV8 and PV15 metal pumps use a revolutionary Pro Flo V air distribution system Proprietary composite seals reduce the coefficient of friction and allow lube free operation Constructed of aluminum the Pro Flo V air distribution system is designed to perform in on off non freezing non stalling tough duty applications Step 1 Using a 9 16 wrench loosen the bolts that connect ...

Страница 22: ... at both ends of the air valve Step 7 Remove the air valve spool from the air valve body by threading one air valve bolt into the end of the air valve spool and gently sliding the spool out of the air valve body Inspect seals for signs of wear and replace entire assembly if necessary Use caution when handling airvalvespooltopreventdamagingseals Note seals should not be removed from assembly Seals ...

Страница 23: ...lier We do not simply sell pump parts we provide value added procurement solutions Our unique network enables us to purchase effectively resulting in low cost solutions We also know that low purchase price is not enough quality integrity and inventory are also important Spectrom is structured to provide Pre and Post sales support giving our customers value added application and pump knowledge Cont...

Страница 24: ...e Nose Pliers Phillips Screwdriver Electrical Tape Wrap electrical tape around each leg of the needle nose pliers heat shrink tubing may also be used This is done to prevent damaging the inside surface of the new seal With a new seal in hand place the two legs of the needle nose pliers inside the seal ring See Figure A Open the pliers as wide as the seal diameter will allow then with two fingers p...

Страница 25: ...TT4454 EOM PV8 PV15M 8 04 TT4267 5 04 23 WILDEN PUMP ENGINEERING LLC ...

Страница 26: ...E X P L O D E D V I E W P A R T S L I S T I N G 17 BALL MUSHROOM ULTRA FLEX TEFLON 16 18 19 17 21 16 19 21 18 26 25 16 12 13 14 15 18 19 21 24 22 36 32 31 30 29 23 2 6 4 3 5 8 11 27 1 12 7 9 2 37 36 32 33 35 34 39 36 32 33 38 34 WILDEN PUMP ENGINEERING LLC 24 TT4454 EOM PV8 PV15M 8 04 TT4267 5 04 ...

Страница 27: ...0 72 08 4600 10 72 Outer Piston Ultra Flex 2 08 4560 10 83 N A 22 Liquid Chamber 2 15 5000 10 83 15 5000 10 83 23 2 Manifold Side Discharge 2 08 5056 10 83 08 5056 10 83 24 12 Clamp Band Assembly2 2 08 7300 03 83 08 7300 03 83 25 12 Clamp Band Wing Nut 4 08 6671 10 08 6671 10 26 12 Clamp Band Washer 3 8 4 04 6741 03 04 6741 03 27 Pump Stand Assembly 1 15 7651 10 83 15 7651 10 83 28 Sanitary Muffle...

Страница 28: ... I S T I N G PV15 SANIFLO LSH Horizontally Mounted No Manifold E X P L O D E D V I E W 5 6 4 1 2 3 8 11 12 7 9 10 31 32 16 13 14 19 20 21 30 15 23 24 27 29 25 28 26 22 WILDEN PUMP ENGINEERING LLC 26 TT4454 EOM PV8 PV15M 8 04 TT4267 5 04 ...

Страница 29: ...er Screw HSFH 3 8 16 X 1 6 71 6250 08 19 Inner Piston 2 08 3700 01 20 Diaphragm 2 21 Outer Piston 2 08 4550 10 72 22 Liquid Chamber 2 15 5000 10 83 23 Flap Valve Body 4 15 5280 10 83 24 Flap Valve3 4 15 1180 10 83 25 4 to 3 Reducer 4 15 5290 10 83 26 3 Manifold Gasket 4 27 4 Manifold Gasket 4 28 3 Clamp Band Assembly 4 15 7102 03 29 4 Clamp Band Assembly 4 15 7202 03 30 12 Clamp band Assembly2 2 0...

Страница 30: ... E D V I E W P A R T S L I S T I N G BALL MUSHROOM ULTRA FLEX TEFLON 16 18 20 21 16 19 21 18 27 26 16 12 13 14 15 18 19 21 25 22 22 35 32 36 34 24 2 6 4 3 5 8 11 28 1 7 9 10 40 39 33 35 38 32 42 39 33 35 41 37 19 30 33 31 23 12 WILDEN PUMP ENGINEERING LLC 28 TT4454 EOM PV8 PV15M 8 04 TT4267 5 04 ...

Страница 31: ...2 08 4560 10 83 N A 22 Liquid Chamber 2 15 5000 10 83 15 5000 10 83 23 3 Elbow 4 15 5240 10 83 15 5240 10 83 24 3 T Section Center Ported 2 15 5160 10 83 15 5160 10 83 25 12 Clamp band Assembly 2 08 7300 03 83 08 7300 03 83 26 12 Clamp Band Wing Nut 4 08 6671 10 08 6671 10 27 12 Clamp Band Washer 3 8 4 04 6740 03 04 6740 03 28 Pump Stand Assembly 1 15 7651 10 83 15 7651 10 83 29 Sanitary Muffler N...

Страница 32: ...SHROOM ULTRA FLEX TEFLON E X P L O D E D V I E W P A R T S L I S T I N G 16 18 20 17 21 16 19 21 18 27 26 13 14 15 18 19 21 25 22 35 33 32 31 30 23 6 4 5 8 11 28 1 12 7 9 10 37 36 32 33 35 34 39 36 32 33 38 34 36 34 24 19 WILDEN PUMP ENGINEERING LLC 30 TT4454 EOM PV8 PV15M 8 04 TT4267 5 04 ...

Страница 33: ...4560 10 83 N A 22 Liquid Chamber 2 15 5000 10 83 15 5000 10 83 23 3 Elbow 2 15 5240 10 83 15 5240 10 83 24 3 T Section Side Ported 2 15 5170 10 83 15 5170 10 83 25 12 Clamp band Assembly 2 08 7300 03 83 08 7300 03 83 26 12 Clamp Band Wing Nut 4 08 6671 10 08 6671 10 27 12 Clamp Band Washer 3 8 4 04 6740 03 04 6740 03 28 Pump Stand Assembly 1 15 7651 10 83 15 7651 10 83 29 Sanitary Muffler Not Show...

Страница 34: ...ot 15 1215 69 yellow dot FDA EPDM 08 1010 74 2 blue dots 08 1020 54 blue dot 04 1080 74 orange dot 15 1375 74 orange dot 15 1215 74 orange dot Saniflex 08 1010 56 cream N A 04 1080 56 cream N A N A Teflon PTFE 08 1010 55 white N A 04 1080 55 white 15 1375 55 white 15 1215 55 white FDA Wil Flex 08 1010 57 off white N A 04 1080 57 off white N A N A Note Teflon PTFE and Ultra Flex diaphragms not avai...

Страница 35: ... control we cannot guarantee the suitability of any pump or part for a particular application and Wilden Pump and Engineering LLC shall not be liable for any consequential damage or expense arising from the use or misuse of its products on any application Responsibility is limited solely to replacement or repair of defective Wilden pumps and parts All decisions as to the cause of failure are the s...