PAGE 7
HC-M12-F
256 REV.030718
TYPICAL HYDRAULIC CIRCUIT
FILTER
RESERVOIR
PRESSURE
RELIEF VALVE
CIRCULATION RETURN LINE
(MUST GO DIRECT TO RESERVOIR)
CONTROL VALVE
(MOTOR SPOOL)
4-WAY SPRING
RETURN TO CENTER
HYDRAULIC
PUMP
800 PSI [55 BAR]
2(US)GPM [8 L/MIN]
REQUIRED FOR MODELS
SUPPLIED WITH EXTERNAL
BRAKE RELEASE OPTION
400 PSI [28 BAR]
PRESSURE REQUIRED
FOR MODELS SUPPLIED
WITH FREESPOOL
OPTION
CIRCULATION SUPPLY LINE
M12: 3.5 (US) GPM [13 LPM]
H12: 4.5 (US) GPM [17 LPM]
(EXTERNAL CIRCULATION
MODELS ONLY)