TRITON SYSTEMS, INC.
SECTION 4 - INSTALLATION/REMOVAL
4-2
FULL MOTION VIDEO - USER GUIDE
•
#8-32, 3/8” PAN head Phillips Screws (10).
•
Adhesive cable clips (5).
Step 1: Install Hightopper Housing.
The FMV Hightopper Housing is pre-assembled at the
factory. The Housing consists of front and rear halves
which mate together.
1-1
Open the FMV shipping box and remove the
FMV Door Panel Assy.
1-2
Unlock and open the control panel of the ATM.
The control panel should remain open and fully
extended during the installation procedure. Turn
off power to the ATM and disconnect the ATM
power cord from the facility power outlet!
1-3
Remove the Hightopper Housing from the
shipping box. Set the Hightopper Housing on
the ATM back housing, as shown in Figure 4-1.
Ensure the Hightopper mounting boss posts
mate together securely with the corresponding
bosses on the ATM, as shown in Figure 4-2.
1-4
Attach the two mounting brackets to secure the
Hightopper Housing to the top of the ATM back
housing. Each bracket is secured using four (4)
of the ten (10) provided Phillips screws (see
Figures 4-3 and 4-4).
1-5
Secure the lower part of the Hightopper Housing
to the ATM back housing (at the mounting
bosses) using the remaining two (2) provided
Phillips screws, as shown in Figure 4-5. The fully
installed Hightopper Housing is shown in Figure
4-6.
1-6
For reference purposes Figure 4-7 shows the
location of key cable clips. The cable clips will
be installed in the applicable steps of this
installation procedure, and are used to secure
the FMV ventilation fan power cable, 4-Pin
Modular Cable and FMV power module cable.
Installation Procedure
This section provides step-by-step instructions for
installing the FMV. The following conditions are
assumed:
•
The ATM cabinet has been installed, and does
not have a standard Lowtopper or Hightopper
light panel installed. If your ATM has an existing
standard Lowtopper or Hightopper installed it
must be removed prior to installing the FMV
Hightopper assembly. See Appendixes B and
C for the applicable removal procedures.
•
The ATM dispenser mechanism has been
removed to provide free access to the interior
of the lower security container.
You will perform the following steps to install the FMV:
1.
Install Hightopper Housing.
2.
Install Hightopper Ventilation Fan Power
Cable.
3.
Install FMV 4-Pin Modular Cable.
4.
Connect Surge Suppressor Module.
5.
Install FMV Power Cable.
6.
Install FMV Door Panel Assy.
7.
Apply power and verify proper operation.
Required Tools
•
#2 Phillips Screwdriver, 6-inches long.
•
#2 Phillips Screwdriver, short shaft (3-4 inches or
less), for removing ATM power supply panel.
Parts Supplied
•
FMV Hightopper Housing (2-part Housing, pre-
assembled).
•
FMV Door Assembly.
•
FMV Power Supply Module.
•
Surge Suppressor Module.
•
Line Sharing Device and Power Module (optional).
•
4-Pin Modular Cables.
•
Hightopper Ventilation Fan w/Power Cable.
•
Ventilation Fan Power Supply Adapter Board.
•
Mounting Brackets (2).
Содержание Triton 96 Series
Страница 6: ......
Страница 7: ...SECTION 1 INTRODUCTION ...
Страница 10: ......
Страница 11: ...SECTION 2 DISPLAY ...
Страница 15: ...SECTION 3 COMPONENTS ...
Страница 23: ...SECTION 4 INSTALLATION AND REMOVAL ...
Страница 43: ...SECTION 5 OPERATION ...
Страница 49: ...SECTION 6 MAINTENANCE ...
Страница 54: ......
Страница 55: ...APPENDIX A SPECIFICATIONS ...
Страница 59: ...APPENDIX B LOWTOPPER SIGN REMOVAL ...
Страница 61: ...APPENDIX C HIGHTOPPER SIGN REMOVAL ...