![Dover PSG Wilden PS1500 Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/dover/psg-wilden-ps1500/psg-wilden-ps1500_manual_2525048009.webp)
WIL-13001-E-01
9
ALLOY C PUMPS
SECTION 5
PS400 ALLOY C
RUBBER-FITTED
Ship Weight………….…Alloy C 45 kg (100 lb)
Air Inlet……………………………………….3/4"
Inlet……………………………...38 mm (1-1/2")
Outlet……………………………38 mm (1-1/2")
Suction Lift………………..…..6.7 m Dry (22.1
′
)
8.6 m Wet (28.4
′
)
Disp. per Stroke
1
……………....1.0 L (0.26 gal)
Max. Flow Rate……………..271 lpm (72 gpm)
Max. Size Solids……………….4.8 mm (3/16")
1
Displacement per stroke was calculated at 4.8
bar (70 psig) air inlet pressure against a 2.1 bar
(30 psig) head pressure.
Example:
To pump 197 lpm (52 gpm) against
a discharge head of 1.4 bar (20 psig) requires
4.1 bar (60 psig) and 54 Nm
3
/h (32 scfm) air
consumption.
Flow rates indicated on chart were determined by pumping water. For optimum life and performance, pumps
should be specified so that daily operation parameters will fall in the center of the pump's performance curve.
Caution: Do not exceed 8.6 bar (125 psig) air supply pressure.
PS400 ALLOY C
FULL-STROKE
PTFE-FITTED
Ship Weight………….…Alloy C 45 kg (100 lb)
Air Inlet……………………………………….3/4"
Inlet……………………………...38 mm (1-1/2")
Outlet……………………………38 mm (1-1/2")
Suction Lift………………..…..6.7 m Dry (22.1
′
)
8.6 m Wet (28.4
′
)
Disp. per Stroke
1
……………....0.9 L (0.25 gal)
Max. Flow Rate……………..348 lpm (92 gpm)
Max. Size Solids……………….4.8 mm (3/16")
1
Displacement per stroke was calculated at 4.8
bar (70 psig) air inlet pressure against a 2.1 bar
(30 psig) head pressure.
Example:
To pump 238 lpm (63 gpm) against
a discharge head of 2.1 bar (30 psig) requires
5.5 bar (80 psig) and 78 Nm
3
/h (46 scfm) air
consumption.
Flow rates indicated on chart were determined by pumping water. For optimum life and performance, pumps
should be specified so that daily operation parameters will fall in the center of the pump's performance curve.
Caution: Do not exceed 8.6 bar (125 psig) air supply pressure.
PERFORMANCE