WIL-11560-E-08
9
PS220/230 Bolted Metal
SECTION 5
PS220/PS230 METAL
RUBBER-FITTED
Ship Weight…………..Aluminum 19 kg (41 lb)
Ductile Iron 29 kg (64 lb)
316 Stainless Steel 31 kg (68 lb)
Air Inlet……………………..…….................1/2"
Inlet…………………………………..25 mm (1")
Outlet………………………………...25 mm (1")
Suction Lift……………………6.9 m Dry (22.7')
9.0 m Wet (29.5')
Disp. Per Stroke
1
…………….0.30 L (0.08 gal)
Max. Flow Rate……………..204 lpm (54 gpm)
Max. Size Solids…………………6.4 mm (1/4")
1
Displacement per stroke was calculated at 4.8
bar (70 psig) air inlet pressure against a 2.1 bar
(30 psig) head pressure.
Example:
To pump 140 lpm (37 gpm) against
a discharge pressure head of 2.8 bar (40
psig) requires 5.5 bar (80 psig) and 60 Nm
3
/h
(38 scfm) air consumption.
Flow rates indicated on chart were determined by pumping water. For optimum life and performance, pumps
should be specified so that daily operation parameters will fall in the center of the pump's performance curve.
Caution: Do not exceed 8.6 bar (125 psig) air supply pressure.
For UL-listed pumps, do not exceed 3.4 bar (50 psig) air supply pressure.
PS220/PS230 METAL
TPE-FITTED
Ship Weight…………..Aluminum 19 kg (41 lb)
Ductile Iron 29 kg (64 lb)
316 Stainless Steel 31 kg (68 lb)
Air Inlet……………………..…….................1/2"
Inlet…………………………………..25 mm (1")
Outlet………………………………...25 mm (1")
Suction Lift……………………5.9 m Dry (19.3')
9.0 m Wet (29.5')
Disp. Per Stroke
1
…………….0.26 L (0.07 gal)
Max. Flow Rate……………..212 lpm (56 gpm)
Max. Size Solids…………………6.4 mm (1/4")
1
Displacement per stroke was calculated at 4.8
bar (70 psig) air inlet pressure against a 2.1 bar
(30 psig) head pressure.
Example:
To pump 144 lpm (38 gpm) against
a discharge head of 2.8 bar (40 psig) requires
5.5 bar (80 psig) and 63 Nm
3
/h (40 scfm) air
consumption.
Flow rates indicated on chart were determined by pumping water. For optimum life and performance, pumps
should be specified so that daily operation parameters will fall in the center of the pump's performance curve.
Caution: Do not exceed 8.6 bar (125 psig) air supply pressure.
For UL-listed pumps, do not exceed 3.4 bar (50 psig) air supply pressure.
PERFORMANCE