3.1 Direct Pump Control (DPC)
Illustration of a DPC Board
3.1.1 Wayne and Gilbarco
Wayne dispensers can connect directly to the DPC interface board or the Wayne Data Distribution Box can
be used. Up to eight (8) dispensers can be connected to control a maximum of 16 fueling points (if the
dispensers are double-sided), or eight (8) fueling points for single-sided dispensers, or any combination.
Gilbarco dispensers can connect directly to the interface board, or the Gilbarco Universal Distribution Box
can be used. Up to eight (8) dispensers can be connected directly to the interface board to control a
maximum of 16 fueling points (eight [8] double-sided), or eight (8) fueling points for 16 single-sided
dispensers, or any combination.
3.1.2 Gasboy
Gasboy dispensers use an RS-232 to RS-485 converter board for isolation and the correct interface. The
dispensers all wire in a 2-wire multi-drop configuration. Up to 16 fueling points can be controlled. This can be
any combination of single- and double-sided dispensers.
3.1.3 DPC Technical Specifications
DPC Technical Specifications
20-8225 Cabinet Dimensions [H x W x D]
10” x 12.5” x 5.69” (25.4 x 32 cm x 14.4 cm)
Power Requirements
115/230 VAC; 50/60 Hz; 1.0/0.06 A
Operating Temperature Range
-40°F - 122°F (-40°C - 50°C)
Dispenser Brands Supported
Gilbarco, Wayne and Gasboy
M1700 FSC3000 Installation Manual | Dover Fueling Solutions
49
Содержание Petro Vend FSC3000
Страница 1: ...Petro Vend FSC3000 Installation Manual Part Number M1700 Revision 15 1 FSC3000 ...
Страница 7: ...Warranty 78 M1700 FSC3000 Installation Manual Dover Fueling Solutions 7 ...
Страница 65: ...3 2 3 3 Gilbarco Secure Prompts DTC M1700 FSC3000 Installation Manual Dover Fueling Solutions 65 ...
Страница 79: ......