![Dover MOUVEX ASX40 Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/dover/mouvex-asx40/mouvex-asx40_instructions-manual_2524988013.webp)
13/19
NT 1101-G00 08.10 AX40 - ASX40 e
4.3.2 ASSEMBLING THE SHOES
1. Check that the shoes have no dents or deep scratches
that may quickly deteriorate the hose.
2. Position the screw
28
with its washer
29
around the
wheel
3
.
3. Slip the special shims
4
.
4. Positon the shoe
5
.
5. Partially tighten the screw
28
.
6. Insert a suitable number of shims in accordance with
the desired service pressure (see § SHIMMING THE
SHOES).
7. Tighten the screw
28
, check that the shoe
5
is correct-
ly aligned with the wheel
3
.
4.4 Setting of pump at service pressure needed
Shims may have to be added under the shoes (see §
SHIMMING THE SHOES).
The cover
2
need not be removed.
4.4.1 ADDING OR TAKING OFF SHIMS
First shoe :
1. Position the shoe
5
facing the window
15
. If the shoe is
not correctly positioned, operate the pump intermittently
until the shoe
5
can be seen through the window
15
.
2. Switch off the electric power supply before any opera-
tion in order to prevent the pump starting unexpectedly.
3. Drain the pump of his lubricant following the instruc-
tions of the § DISASSEMBLING THE HOSE.
4. Loosen the screws
37
and remove the washers
38
.
5. Remove the window
15
.
6. Remove the window seal
46
.
7. Partially untighten the screw
28
.
8. Place the suitable number of shims
4
(see § SHIMMING
THE SHOES).
9. Tighten the screw
28
, check that the shoe
5
is correctly
aligned with the wheel
3
(see § ASSEMBLING THE
SHOES).
10. Check the window seal
46
, change it if necessary.
11. Position the window
15
with its seal
46
.
12. Tighten the screws
37
, with their washers
38
. Once
the screws are tightened, the seal must be squeezed
all over.
13. Switch on electric power supply.
Second shoe :
Repeat the previous steps from 1 to 13.
NOTE
There must be the same number of shims under each
shoe.
NOTE
Do not loosen the shoe screw
28
completely.
CAUTION
Slippery lubricant.
Spills should be
cleaned up.
THE PUMP LUBRICANT IS VERY SLIPPERY
AND MAY CAUSE SERIOUS INJURY.
ANY SPILLS MUST BE CLEANED UP.
Right position of the shoe
Wrong position of the shoe
WARNING
Dangerous voltage.
Can cause
injury and death
.
DISCONNECT THE ELECTRICITY SUPPLY
BEFORE ANY MAINTENANCE OPERATION.
4. MAINTENANCE OPERATIONS (continued)