Safety - Installation
Instruction manual
8
■ Installation requirements
Installation must be performed without fail by a Markem-Imaje
technicians team. Any person modifying the installation shall be
wholly liable for such modification.
The printer must be installed in accordance with applicable
requirements.
The Model 5200 can have up to two printheads.
The Model 5400 can have up to four printheads.
Determine a location for the printer that:
• Provides access to the front and rear of the enclosure,
including a minimum of 15cm (6”) clearance in the rear for
adequate cooling ventilation.
• Positions the printhead(s) within 3m (10’) of the enclosure.
• Provides sturdy, level floor space.
• Meets environmental and electrical specifications.
Ensure the electrical requirements are satisfied:
• The printer must be connected to a 50–60Hz, single-phase
AC power supply electricity network, 1450W maximum (Model
5200) or 2530W maximum (Model 5400), with earth ground
using the cable supplied with the printer.
• The end user is responsible for supplying an appropriate plug
or wiring to a terminal block on the AC power cord.
• The AC voltage configuration must be verified or changed to
match the end user’s AC voltage service.
• For electrical characteristics, see the Serial/I.D./Rating Label
on the rear of the enclosure, near the power switch.