Coolgenix™ Case Cleaning Checklist 

 
 

 
 

Pre-Cleaning Check List 

  Identify the cases that need to be cleaned (Note:  Multiple cases usually run on the same 

refrigeration circuit, so plan on cleaning all cases on that circuit at one time) 

  Post safety signs in the area of the cases that are going to be cleaned 

  Remove the product from the cases and relocate to a refrigerated storage area 

  Turn off the refrigeration to the cases, there are several options: 

  Turn off at the power supply 

  If your case is equipped with a clean switch button, push the button.  The push button allows 

for a 90 minute delay and will automatically turn back on after 90 minutes 

  If your case is equipped with a cleaning toggle switch, flip the manual toggle off to clean and 

manually flip back on when case is cleaned 

  If you are unable to turn the refrigeration off to the case by the above methods, put the case 

in a manual defrost through the Dixell Controller -   

Push the 

DOWN

 key for more than 2 seconds and a manual defrost will start on 

the Dixell Controller.  The controller must be turned back on when finished 
cleaning. 
 

  If your case is equipped by a different type of controller, refer to the controller manual for 

putting the case into manual defrost for case cleaning 

  Turn off the electrical circuits to the case at the power supply 

  Wait until the Coolgenix deck pans are room temperature before removing - the center pan will 

have a sensor attached on the bottom of the deck pan, detach the 
sensor before removing the pan 

 
 
 
 
 

  Visually inspect the cases for debris and ice 

  Check the drain to make sure it is not clogged 

  Gather all necessary cleaning materials 

  Mild cleaning solution 

 Sanitizer 

!

CAUTION 

Do not perform these procedures until you have been properly trained by store personnel to clean 
the cases or watched the Hillphoenix Case Cleaning Guidelines video.  Make sure you follow safety 
procedures outlined by your organization and abide by any state and local codes that may apply.

 

Location of pan sensor found on the  
bottom of the center deck pan in the  
display case. 

Содержание Hillphoenix Coolgenix

Страница 1: ...oller Push the DOWN key for more than 2 seconds and a manual defrost will start on the Dixell Controller The controller must be turned back on when finished cleaning If your case is equipped by a different type of controller refer to the controller manual for putting the case into manual defrost for case cleaning Turn off the electrical circuits to the case at the power supply Wait until the Coolg...

Страница 2: ...k Replace the rear doors into the tracks 3 Clean the Coolgenix display pans and interior components Depending on the case design the front glass will lift or swingout to access the Coolgenix pans Make sure the surface of the pan is room temperature before cleaning If you have not done so already remove the pan sensor located on the bottom of the center pan in the case If the case is equipped with ...

Страница 3: ...5 Clean the front glass For standard glass use a mild glass cleaner and a clean paper towel or cloth to wipe the glass For non glare glass refer to special cleaning instructions contained on the CD or in the case installation manual 6 Clean prep areas Remove cutting board Spray the cutting board with a mild cleaning solution and wipe it down with a paper towels or a clean cloth Spray the cutting b...

Страница 4: ... bars are set back in place to prevent the pans from warping If you have Coolgenix deck pans with disconnects reconnect the pan to the quick connect hose Reconnect the sensor to the center pan and insure proper contact The sensor is essential for the case to PROPERLY FUNCTION AND MAINTAIN PROPER PRODUCT TEMPERATURES Once proper temperature is established in the case restock the case according to t...

Отзывы: