18
14. Removal of Pressure Switch
a.
Tilt kettle 90°.
b.
Remove bottom cover.
c.
Unplug red and white wires.
d.
Unscrew switch from 90° elbow and
remove.
15. Install Pressure Switch
a.
Tilt kettle 90°.
b.
Screw switch into elbow.
c.
Plug in red and white wires.
d.
Replace bottom cover. Tighten screws
and gasket to 10-12 in-lb torque.
e.
Check water level.
f.
Remove air from jacket.
16. Removal of Water Level Probe
a.
Tilt kettle 90°.
b.
Remove bottom cover.
c.
Remove blue wire from probe.
d.
Unscrew probe from jacket and remove.
17. Install Water Level Probe
a.
Tilt kettle 90°.
b.
Screw probe into kettle jacket.
c.
Connect blue wire.
d.
Reinstall bottom cover. Tighten screws
and gasket to 10-12 in-lb torque.
e.
Check water level.
f.
Remove air from jacket.
NOTE:
HEATER ELEMENTS CAN
NOT
BE
REPLACED. IF THE KETTLE DOES NOT
HEAT PROPERLY AND THE HEATER
ELEMENTS SHOW AN OPEN CIRCUIT, THE
KETTLE MUST BE REPLACED.
Cleaning
1.
Suggested Cleaning Supplies:
a.
Cleaner, such as Klenzade HC-10 or
HC-32 from ECOLAB, Inc.
b.
Kettle brushes in good condition.
c.
Sanitizer such as Klenzade XY-12.
d.
Film remover such as Klenzade LC-30.
2.
Precautions
Before any cleaning operation, shut off the
kettle by turning the thermostat dial to
"OFF", and shut off all electric power to the
unit at a remote switch, such as the circuit
breaker.
WARNING
KEEP WATER AND SOLUTIONS OUT OF
CONTROLS AND BURNERS. DO NOT USE
A HIGH PRESSURE HOSE TO CLEAN THE
CONTROL CONSOLE, ELECTRICAL
CONNECTIONS, ETC.
3. Procedure
a.
Clean food contact surfaces
as soon as
possible after use, preferably while the
kettle is still warm. If the unit is in
continuous use, clean and sanitize
inside and outside at least once every
12 hours.
b.
Scrape and flush out large amounts of
food residues. Be careful not to scratch
the kettle with metal implements.
CAUTION
NEVER LEAVE A CHLORINE SANITIZER IN
CONTACT WITH STAINLESS STEEL
SURFACES FOR LONGER THAN 30
MINUTES. LONGER CONTACT CAN
CAUSE CORROSION.
WARNING
AVOID DIRECT CONTACT WITH HOT
SURFACES. DIRECT SKIN CONTACT
COULD RESULT IN SEVERE BURNS.
c. Prepare a solution of the
detergent/cleaning compound as
instructed by the supplier.
Clean
the
unit thoroughly. A cloth moistened with
cleaning solution can be used to clean
controls, housing, electrical conduit, etc.
d.
Rinse the kettle thoroughly with hot
water. Then drain completely.
Содержание Groen TDB Series
Страница 26: ...26 Schematics 440V 3 Phase 60 Hz ...