Service Manual
TC1 TOOL CHANGER
9
Rev. A
24 Nov 2020
3. Electric Modules
Electric power and signal modules are available in various configurations. See Table 4 for compatibility
with master and tool plates.
Electric Module Replacement
1.
Remove all pneumatic and electric power sources from the tool changer before servicing
the electric modules. Servicing or maintaining the tool changer without isolating it from pneumatic and
electric power sources may result in electric shock and personal injury.
2. Remove the existing electric module by disconnecting the electrical connector and unscrewing the M3
screws using 2.5mm hex key wrench (see Fig.9 or Fig.10).
3. Place the new electric module in the same position, apply Loctite 242, 243, or equivalent to the screws
and tighten to 0.9 Nm using the 2.5mm hex key wrench. Reconnect the electrical connector.
Fig.9
TABLE 4
ITEM
PART NUMBER
DESCRIPTION
COMPATIBILITY
1
TC1-E01M-C01
8 PIN M8 SOCKET ELECTRICAL PASS-THRU MASTER MODULE
TC1-050M-XX
2
TC1-E01T-C01
8 PIN M8 PLUG ELECTRICAL PASS-THRU TOOL MODULE
TC1-050T-XX
3
TC1-E01T-P01
PNP MAGNETO RESISTIVE 4MM SENSING MODULE
3
TC1-E01T-N01
NPN MAGNETO RESISTIVE 4MM SENSING MODULE
M3 FLAT HEAD
SCREW
MASTER ELECTRICAL
MODULE
MASTER
PLATE
2.5mm HEX KEY WRENCH
0.9Nm
THREAD LOCKER
242/
243
9
TC1
Service Manual
Содержание DESTACO TC1 Series
Страница 2: ......