1.94
DPL SERIES MAINTENANCE
DPL Series Assembled View
Item Qty Name
01
1
Body
02
2
Piston
04
4
Cap
05
1
Axis
06
2
Jaw
08
1
Shielded Case
50
4
Seal, Cap
51
1
Synchronization Pinion
52
2
Set Screw-Manifold Port Plugs
53
4
Retainer Ring, Cap
54
4
Piston Ring Guidance
55
4
Piston U-Cup
56
4
Magnet
57
2
Drive Pin Retainer Ring
58
2
Stopper-Manifold Port Plugs
59
2
Drive Pin
60
2
Center Retaining Ring
63
4
Jaw Dowel Pin
64
6
Shielded Case Screws
NOTE:
Contact the Robohand Sales Department for a
complete spare parts list with order numbers and prices.
4
53
50
54
55
59
57
2
6
63
8
64
1
Accessory Installation & Adjustment Instructions
77
78
Installation - Inductive Sensors Holder Kit
1) Place the flags (#2) on the jaws as shown.
2) Install the sensor holder (#72) on the
adapter (#73) using the screws (#75)
3) Tighten the sensor (not shown) into the
sensor holder(#73).
4) Install the nut (#71) into the slot of the
body and the adapter (#72) on the slot.
Install the screw (#74) to fix the adapter
on the nut.
5) Loosen the screw (#74) and slide the
assembly until the light indicates.
6) Tighten the screw (#74).
Installation - In-Line Jaws
1) Install the interface (#77) onto the jaws.
When combined with the
-R
option and
according to the mounting direction, the
interface can be used for internal or
external clamping.
2) Tighten the screw (#78) between the
interface (#77) and the jaw.
72
74
75
73
71