background image

Instruction Manual

Seven Keys:

DOWN, MODE, SNOOZE/LIGHT, CHANNEL, UP, ALERTS, ALARM.

1. Display Unit

• 12/24 h Time and Date.(Press “DOWN” key to switch) 

• Dual alarms.

• Snooze function (snooze interval optional from 3 minutes to 20 minutes,default: 

  5 minutes).

• RCC: WWVB(US) [ One product only have one RCC channel ].

• °C/°F switch over.(Press “UP” key to switch) 

• Weather forecast.

• Indoor temperature range: 0°C-50°C (32°F-122°F), accurate range: ±1°C( ±1.8°F), display

  scope: 0°C - 50°C (32°F-122°F).

• Indoor humidity range: 25%-95% accurate range: ± 5%, humidity display scope: 20%-99%.

• Outdoor temperature range: -35°C-60°C (-31°F-140°F), accurate range: ±1°C( ±1.8°F),

  temperature display scope: -40°C-70°C(-40°F-158°F).

• Outdoor humidity range: 25%-95%, accurate range: ±5%, humidity display scope: 20%-  

  99%.

• Temperature alert for both highest and lowest indoor and outdoor temperature.

• RF 433MHz outdoor Temperature/Humidity signal transmission, up to 3 outdoor

  transmitters receivable( Product only come with 1 outdoor transmitter, please contact the

  seller if you need more outdoor transmitters).

• Battery low-power indicator.

• Comfort level.

• Adjustable backlight (High light, mid-bright, turn off).

• Color backlight function (Light on for 8 seconds when powered by batteries).

• Color backlight (Sound control).

2. Operation Instruction

Insert battery (AAA) or connect adapter after a few seconds, LCD shows full segment, 

after sound beep, it will enter the common display mode.

• On Default:

  WWVB: Default 12-hour system at 12:00, temperature unit default°F.

3. Key Function

3.1 Time Setting

• Under normal mode, press and hold “MODE” for a few seconds to set the time (Hold until

  the displa

y fl

ashes). And then press “MODE” key to choose the item for setting.The steps

  when in time setting mode: 

  Time zone

Hour

Minute

Year—Month—Day—Week—>Exit.

A. Press "UP" key, the number will go up; press and hold for 3 seconds, the number will 

    continually going up.

B. Press "DOWN" key, the number will go down; press and hold for 3 seconds,the number

    will continually going down. Finish setting when no keys are pressed for 10 seconds, and

    set numbers will be saved.

3.2  Temperature and Humidity Function

• Under normal mode, press the “CHANNEL” key to switch the channel of the outdoor 

  display, switch in sequence: CH1 temperature and humidity

CH2 temperature and 

  humidity

CH3 temperature and humidity

cycle display,(symbol  appears on the LCD 

  display). Press and hold “CHANNEL" key for a few seconds to connect/reconnect the 

  outdoor temperature sensor in 3 minutes.

-1-

Содержание S657

Страница 1: ... sure that both the Main Unit and the Outdoor Sensor are power on within 3 minutes If the Main Unit is powered for over 3 minutes without the sensor on it will not pair with the Outdoor Sensor or receive signal anymore ...

Страница 2: ... Color backlight function Light on for 8 seconds when powered by batteries Color backlight Sound control 2 Operation Instruction Insert battery AAA or connect adapter after a few seconds LCD shows full segment after sound beep it will enter the common display mode On Default WWVB Default 12 hour system at 12 00 temperature unit default F 3 Key Function 3 1 Time Setting Under normal mode press and ...

Страница 3: ...l mode Press ALARM to turn on off the alarm in sequence AL1 ON AL2ON AL1 and AL2 On ALI and AI2 Off 3 4 SNOOZE LIGHT KEY Under normal mode press SNOOZE LIGHT key to adjust brightness Adjust in sequence when powered by adapter Bright normal turn off bright loop Adjust in sequence when powered by batteries Bright normal bright loop Under alarm mode press SNOOZE LIGHT key for a few seconds to enter snoo...

Страница 4: ...eceived the RCC symbol and parabolic antenna will flash when the signal received successfully theRCC symbol will display on the LCD display without flashing C When the signal is weak and cannot be distinguished RCC symbol will flash D When the signal is received the signal will display and stop receiving During signal receiving press the DOWN key to exit radio signal receiving Press the SNOOZE LIGHT ...

Страница 5: ... DRY When the humidity is less than 40 No comfort level shown on the display when the temperature is out of the appropriate range 20 C 28 C 68 F 82 4 F and the humidity is between 40 70 4 Other Functions 4 1 Alarm Function Under time mode press ALARM to turn on off the alarm in sequence AL1 ON AL2 ON AL1 and AL2 ON AL1 and AL2 OFF When the alarm is turned on and the alarm reaches the set time it ri...

Страница 6: ...perature alert mode press the UP key or DOWN key to turn the alarm on off After Alarm is set On the corresponding alarm symbol will display Under time mode press and hold ALERTS key for a few seconds until the display flashes press the ALERTS key to set 4 temperature alerts In order of highest temperature outdoor lowest temperature outdoor highest temperature indoor lowest temperature indoor Indoor ...

Страница 7: ...hy does the Weather Station and outdoor sensor lose connection A Radio signals Easily absorbed by metal objects and not easy to penetrate the wall therefore the distance in actual use will be much shorter than 80 meters theoretical value B Host s receiving channel doesn t corresponding with outdoor sensor s channel C There s similar signal in the environment this signal will be automatically recei...

Отзывы: