Select the filter cartridge options supplied for stages A or B in accordance with 
your requirements.

Screw the thread of each filter cartridge into the relevant cap inside the filter 
head until washer resistance is felt – do not over-tighten.

If there is less than 10 inches clearance below the base of the filter housing, 
place the filter body in position over the cartridge before screwing the cartridge 
into the cap.

Moisten the O ring on each filter body, check that it is located correctly and then 
screw the body to the filter head. Hand tighten only.

2.  Conditioning the Ceramic Cartridge

The filter system should now be ready for pressurisation. With the user tap in the 
on position, gradually open the upstream isolation valve until the flow from the 
tap has stabilised at the recommended flow rate.

Close the user tap and ensure that the system is watertight.

In order to remove any loose particles resulting from the manufacturing process 
or from cleaning the cartridge, it is recommended that the first supply of filtered 
water should be run to waste for 10 minutes.

For a new cartridge, the maximum flow rate will be achieved once the ceramic 
filter  cartridge has become fully saturated; to allow the cartridge to be 
conditioned to the source water, allow the unit to stand unused for a further  
24 hours and then run the first 15 litres of water to waste.

The filter is now ready for use

Due to filtration of particulate contaminants from the water during use, the flow 
of the water from the filter may deteriorate over a period of time. To restore the 
water flow to its normal level, simply remove, clean and replace the cartridge as 
follows: 

3.  Servicing the Filters 

It is important to wear rubber gloves or wash your hands thoroughly before and 
after servicing the filter and cartridges.

Removal, cleaning and reinstallation/replacement of the cartridges is carried out 
as follows:

With the upstream isolation valve turned off, vent any pressure by opening the 
user tap. 

Place a bowl under the filter body and, using the wrench provided; unscrew the 
filter body which will be full of water. Lower the body into the bowl.  
The cartridges can now be unscrewed from the cap and cleaned in accordance 
with the distributor’s instruction or replaced as described in Section 1.4.

When the cartridge have been re-installed, wipe the filter housing clean with a 
damp cloth and refill the filter as described in Section 2.

Cleaning/Sterilising the System 

To clean the housing wipe externally with a warm damp cloth. The following 
substances should be avoided:

• 

Strong oxidising agents such as bleach or Milton solution

• 

All strong acidic materials including some descalents

• 

Strong alkaline material 

A cartridge that has reached the end of its life would be indicated by a reduction 
in the taste quality of the filtered water. The cartridge should be replaced in 
accordance with the rated service capacity, which would typically give a period of 
six months usage. 

W2393050 Issue 3    October 2016   Fairey Industrial Ceramics Limited trading as Doulton Water Filters.

Manufactured by: 

Doulton Water Filters, Newcastle, Staffordshire, ST5 9BT, United Kingdom.
Telephone: 

+44 (0) 1782 664420

Fax: 

+44 (0) 1782 664490

Email: [email protected]
Website: www.doulton.com

Doulton

®

 is a trademark registered to Fairey Industrial Ceramics Limited.

www.doulton.com

A GENUINE WATER FILTER