HIP DUO

 Filter  

 

Installation and  
Conditioning Instructions

Parts & Service Availability:

Important

 – Always use genuine Doulton

®

 replacement cartridges and 

components to guarantee the manufacturer’s performance claims. 

Contact your local Doulton

®

 distributor for sales, service, replacement parts and 

for the range of available replacement filter cartridges.

Technical Data:

Maximum working pressure: 

100 psig (689kPa) See 1.1

Maximum working temperature: 

30°C (86°F) 

Minimum working pressure: 

20 psig (138kPa)

Installation of Cartridges 

(as advised by your distributor depending on your water quality)

Direction of Flow

 

 B

 

  2 Stage Filter 

A:  Pre filter or water treatment cartridge

B:  Ceramic filter element 

1. Installation

Note

 - The filter cannot be used for the treatment of hot water and should only 

be connected to the cold water supply. 

1.1  Pressure Information

Due to the potential wide variations of pressures from one installation to 
another the manufacturer advises that

 if there is any concern that the 

system would see pressures above 100 psig (approx. 6.9bar) then an 
approved pressure reducing valve bought from a good hardware store 
and set at 100 psig (approx. 6.9 bar) should be installed

 upstream of the 

filter to eliminate any extreme variations in pressure. Water fittings for use in 
permanently pressurised systems may have a finite life.  It is important that the 
plastic components in the system are replaced after 10 years usage. 

1.2  Selecting a Position for the Filter 

The filter should be fixed inside a unit or to a wall with the screws provided, 
near to the incoming water supply and the user tap.  Make sure that the filter is 
located so that the connecting pipework does not have any sharp bends in it.  

For easy servicing of the filter there should be at least 4 inches of 
clearance below the body of the filter

 to allow for removal of the cartridge 

for cleaning or renewal. 

1.3  Connecting Pipework & Fittings

The filter is supplied with 3/8” (inch) pushfit connections. Medium density 
polyethylene tubing is recommended. 

Important 

- Tubing must conform to the following tolerances:

Tubing Dimensions:

Head Type 

Nominal 

Tolerance 

 

 

 

+  

 

-

3/8”   

3/8” 

.001”     

.004”

 
An isolation valve and non-return valve should be fitted upstream of the filter 
(these are required by law in the UK).  The isolation valve may be used to regulate 
the maximum flow rate in accordance with the requirements of the cartridges 
used.

Having selected the appropriate fittings, a user valve/faucet should be installed 
in accordance with the manufacturer’s instructions in a convenient position and 
then connected to the filter.

1.4  Assembling & Fixing the Filter 

Having chosen a position for the water filter, remove the clip on cover from the 
top of the filter head to expose the fixing slots and mark the position of the fixing 
screws onto the wall/unit.  Attach the filter head to the wall/unit with the fixing 
screws provided.

With the water supply isolated connect the upstream and downstream pipework 
to the filter ensuring that the arrow inside the head is showing  
the correct direction of flow and that piping/fittings  
are pushed into the push fittings to a minimum of  
18mm (.75”) depth.

www.doulton.com

A GENUINE WATER FILTER

A GENUINE 

WATER FILTER