Doulton EcoFast Скачать руководство пользователя страница 2

 

Detailed guide to fitting the filter element - figures 2, 3, 4 & 5

1.    Locate the filter in an upright position near to the incoming cold water supply and the user 

tap/faucet.

2.    Ensure that the connecting pipework will not have any sharp bends in it and allow at least 

100mm (4”) of clearance below the assembled filter for removal of the cartridge to service 
or replace -

 see figure 2.

 

Mark the required head position for fixing.

3.   Grip the grey filter cap, twist to the ‘unlock’ position - 

see figure 3.

4.   Pull down to disengage the filter cap from the head.

5.   Fix the filter head to the unit or wall with the 3 screws provided.

6.   Unscrew the filter body from the filter cap.

7.   Open the filter and discard the protective bubble bag from the filter element.

8.  

 

Screw the threaded element mount stem into the grey cap until washer resistance is felt.  

Do not over-tighten - see figure 4. 

9.    Screw the white filter body into the grey filter cap until a positive stop is felt - 

see figure 4.

 Note: 

The inside of the filter cap is greased. Before screwing together ensure no dirt or 

particles are stuck to either the filter cap or filter body ‘O’ ring. 

10.     Align the arrows to the unlock position and push the assembled filter firmly into the head 

until it clicks into position - 

see figure 5.

11.    Twist the white filter body until the locked position on the head is reached - 

see figure 5.

12.   Check that the arrows align to ensure that the filter is fully locked -

 see figure 5

.

 

Select correct pipe for installation

The filter is supplied in either 3/8” or 1/4” push-fit versions to allow connection to your water 
supply and faucet using either 3/8” or 1/4” flexible, medium density polyethylene tubing.  
A user valve/faucet should be installed in accordance with the manufacturer’s instructions in a 
convenient position and then connected downstream of the filter. For advice on the tubing and 
fittings required to connect your filter please contact a reputable dealer/agent.

Connecting the filter

Turn off the cold water supply and connect the inlet tubing to the inlet port of the filter. Connect 
the outlet tubing to the other side of the filter -

 see figure 6.

 Check that the arrows on the ports 

of the head are pointing in the correct direction of flow and that the tubing is pushed into the 
fittings 

to a minimum of 18mm (0.75”) depth

.

 

Figure 3

Figure 5

Figure 4

Figure 2

Filter Head

Filter Cap

Filter Body

100mm / 4 inches

 

 

Figure 6

Direction of flow

Incoming 

mains water

To user 

faucet

Содержание EcoFast

Страница 1: ...ation of the neck of the filter cap and stem of the filter element mount by contact with unfiltered water or dirty hands after cleaning the filter element surface Connecting Pipework and Fittings for either the 1 4 or 3 8 models The filter is supplied with pushfit connections Medium density polyethylene tubing from a reputable supplier is recommended An isolation valve and non return valve should ...

Страница 2: ...10 Align the arrows to the unlock position and push the assembled filter firmly into the head until it clicks into position see figure 5 11 Twist the white filter body until the locked position on the head is reached see figure 5 12 Check that the arrows align to ensure that the filter is fully locked see figure 5 Select correct pipe for installation The filter is supplied in either 3 8 or 1 4 pus...

Страница 3: ...th unfiltered water 5 Disconnect the filter element by either twisting and pulling or unscrewing depending upon the type of element used whilst holding the filter cap Care must be taken to prevent contamination of the neck of the filter cap and filter element mount stem 6 Replace the filter element or clean as described in the following section and then wash your hands Note If replacing with a new...

Страница 4: ...ructural test criteria However due to the potential wide variations of pressures from one installation to another the manufacturer advises that if there is any concern that the system would see pressures above 6 bar then an approved pressure reducing valve set at 6 bar should be installed upstream of the filter to eliminate any extreme variations of pressure Note Water fittings for use in permanen...

Отзывы: