29
28
5.9 Alerts
Beeper sounds once each 30 seconds for
1 second, red LED blinks each 3 seconds –
measured values exceeds selected alarm
settings(not with standard settings). Via Software
LogConnect alarm levels can be set.
If an alarm level has been occurred a X will be displayed on the display bottom.
On the corresponding PDF-report the alarm status will be indicated, too.
If the measurement channel is displayed where an alarm occurred the X on the right
bottom of the display is blinking.
The X disappears when the instrument has been restarted for recording!
Red LED blinks once each 4 seconds.
Replace battery.
Blinks twice or more each 4 sconds. Hardware
fault!
5.8.1 Set Date and Time after battery replacement via button
After battery replacement or power interrupt the instrument automatically changes
into the configuration mode to set date, time and interval. If no button will be pressed
for 20 seconds the unit proceeds with the last date and time in memory:
Press N=
No changing of date
and time, or Press
Y=Yes for changing
date and time
Press Mode-button to increase the value,
press Start-button for jumping to the next
value.
After date-time-request the Interval (INT) can
be changed.
Press N= No to
abort changes,
or Press
Y=Yes to
confirm changes
→
→
→
→
...
* Download free LogConnect software:
www.dostmann-electronic.de/home.html ->Downloads ->Software/<your logger>/
Software/LogConnect_XXX.zip (XXX choose latest version)
6. Technical data
Temperature
Measuring range:
-40..+70°C
Resolution: 0.1°C
Pressure
only
LOG220 /LOG220 E
Measuring range:
300-1100hPa
Resolution:
0.1 hPa
Memory:
LOG200:
150.000 measurements (Temp.+ motion)
LOG210:
100.000 data set (Temp., Humidity, dewpoint and motion)
LOG220:
60.000 data set
(Temp., Humidity, pressure, dewpoint and motion)
LOG200 TC:
60.000 measurements
(Temp.+ 2 external thermocouples T1, T2 + motion)
LOG210 TC:
60.000 measurements
(Temp., Humidity, dewpoint, + 2 external thermocouples
T1, T2 and motion)
LOG200 E:
100.000 measurements (Temp.+ motion)
LOG220 E:
60.000 measurements (Temp., Humidity, pressure, CO
2
dew point and motion)
Interface:
USB (integr.)
Dimensions:
91.5 x 42 x 20 mm
Weight:
Approx. 83 g, Incl. Wall holder
Battery:
1 x 3,6 Volt Lithium ½ AA
Note!
After replacing the battery please check the correct time and date of
the internal clock. For setting the time see next chapter or 5.2.2.1 Configuration
software LogConnect.
6.1 Risk of injury:
• Keep these devices and the batteries out of reach of children.
• Batteries contain harmful acids and may be hazardous if swallowed. If a battery
is swallowed, this can lead to serious internal burns and death within two hours.
If you suspect a battery could have been swallowed or otherwise caught in the
body, seek medical help immediately.
Rel. Humidity
only
LOG210/LOG220/LOG210 TC/
LOG220 E
Measuring range:
0..100%rF
Resolution:
0.1%rF
CO
2
only LOG220 E
Measuring range:
400-10000 ppm
Resolution:
1 ppm