Periodic Maintenance
25
Change return line filter after the first 50 hours of operation, and every 250 hours
thereafter.
1. Contact manufacturer for replacement filter (part number listed in parts breakdown)
2. Shut down the engine on the Log Splitter.
3. Relieve hydraulic system pressure by moving the splitter control lever back and forth
several times.
4. Unthread the canister and discard it along with the accompanying seal. Note: A strap
wrench may be required. Not provided.
5. Apply a small amount of lubricant to the new canister seal.
6. Install the new canister and hand tighten 3/8 to 1/2 turn after gasket makes contact with
head.
3. Spark arrestor
muffler
If the engine is equipped with a spark arrestor muffler, clean and inspect it regularly
(follow manufacturer’s service instruction).
Replace if damaged.