SOUND VIBRATION EMITTED BY THE PUMP 

 
Below are the results of the phonometric measurements carried out on the series pumps

These tests were carried out by an external laboratory in compliance with Directives and Standards UNI 
EN ISO 3744:2009 and Directive ISO 2002/44/EC. 
 

Investigation table of phonometric pressure 

 

Model 

B 125N

 

Condition of pressurised pump

 

Maximum sound emission 

on the surface 

Average level of 

pressure on the surface. 

Level of 

sound power 

dB(A)  

 71.7

 

dB(A)  

 67.9

 

dB(A)  

 71.4

 

 

Model 

B 175N

 

Condition of pressurised pump

 

Maximum sound emission 

on the surface 

Average level of 

pressure on the surface. 

Level of 

sound power 

dB(A)  

 76.7

 

dB(A)

   73.2

 

dB(A)

   76.7

 

 

Model 

B 250N

 

Condition of pressurised pump

 

Maximum sound emission 

on the surface 

Average level of 

pressure on the surface. 

Level of 

sound power 

dB(A)  

 79.3

 

dB(A)  

 75.6

 

dB(A)  

 79.1

 

 

 

 

OPERATIONS TO BE PERFORMED ON THE HEAD 

 

 

Periodical check of the head 

 
Failures or malfunctions may occur due to negligence leading to extraordinary maintenance: proceeding 
with  a  periodical  visual  check,  as  described  in  the 

SR  REDUCER  manual,  preventive  maintenance 

chapter

. It is, at times, possible to avoid the arising of situations that require extraordinary maintenance. 

 
 
 
 

In  the  presence  of  these  anomalies  we  recommend  readily 
intervening  in  order  to  avoid  safety  problems,  a  reduced  flow 
rate and reduced efficiency of the pump.

 

 
Summarising, the checks to be carried out are: 

 

 

Periodical  checks  of  the  pumping  head  must  be  carried  out  to 
ensure that the pump is safe and operating correctly. 

 

Particular attention must be taken if the head installed is made 
of  plastic  as  it  is  more  sensitive  to  temperature  variations  and 
settling phenomena.

 

 

Check  for  oil  leaks  from  the  filler  and  drain  caps,  from  the 
diaphragm  pinching  or  from  the  piston  seal.  Any  one  of  these 
leaks  may  initially  cause  a  decrease  in  the  flow  rate,  followed 
by the breaking of the diaphragm at a later date. 

 

Check for dosed liquid leaks from the valves. 
 

 

 

Chapter 

3

 

3.1 

2.2 

 

ATTENTION! 

Содержание B 125N-12

Страница 1: ... AND MAINTENANCE MANUAL PUMPING HEADS ATTENTION Industrial machinery for professional use These instructions are for qualified personnel Translation of the original instructions EN METERING PUMP WITH SPRING RETURN SR Series mod B HYDRAULIC DIAPHRAGM B 125N B 175N B 250N ...

Страница 2: ...CHNICAL DATA 4 2 1 Technical data of pump 4 2 2 Sound vibration emitted by the pump 6 3 OPERATIONS TO BE PERFORMED ON THE HEAD 6 3 1 Periodical check of head 6 3 2 Troubleshooting 7 3 3 Head disassembly and diaphragm replacement 8 3 4 Piston disassembly and re assembly 9 3 5 Filling of oil chamber 9 3 6 Routine maintenance 10 ...

Страница 3: ...ance of the heads hydraulic part of the hydraulic diaphragm spring return metering pumps model B 125N B 175N B250 N This manual is supplied together with the SR series pumps model A B BR SD D use and maintenance manual to be consulted for any further information and which contains the CE declaration of conformity 1 1 1 ...

Страница 4: ...l h B 125N 8 1 5 1 8 2 4 3 3 20 10 50 AB 3 AC 3 1 2 B 125N 12 2 7 3 2 4 5 5 4 7 4 9 9 AB 3 AC 3 1 2 B 125N 18 6 6 7 9 11 13 2 18 22 22 70 AB 5 AC 4 1 2 B 125N 25 12 6 15 1 21 25 2 34 42 42 AB 5 AC 5 1 2 B 125N 30 18 21 6 30 36 49 60 60 14 20 AB 6 AC 8 1 2 B 125N 40 32 5 39 54 65 89 108 108 8 13 2 8 10 90 AB 8 AC 8 1 2 Characteristic data Model B 175N FREQUENCY Hz 50 60 50 60 50 60 Max pressure bar...

Страница 5: ... 60 ND AB 3 1 2 B 125N 18 6 6 7 9 11 13 2 18 22 22 40 60 70 AB 5 1 2 B 125N 25 12 6 15 1 21 25 2 34 42 42 ND 34 AB 5 1 2 B 125N 30 18 21 6 30 36 49 60 60 ND 23 AB 6 1 2 Characteristic data Model AP B 175N FREQUENCY Hz 50 60 50 60 50 60 Max pressure bar Kg cm 2 Diaphragm Valves REDUCTION RATIO F 1 20 C 1 14 5 B 1 11 5 AISI 316 Ø mm AISI Att Ø STROKES min 1 70 84 96 116 120 0 25 kW 0 37 kW Type G m ...

Страница 6: ... ON THE HEAD Periodical check of the head Failures or malfunctions may occur due to negligence leading to extraordinary maintenance proceeding with a periodical visual check as described in the SR REDUCER manual preventive maintenance chapter It is at times possible to avoid the arising of situations that require extraordinary maintenance In the presence of these anomalies we recommend readily int...

Страница 7: ...tion dampener 4 incorrectly connected motor Check the motor plate again for the correct wiring sequence Check the phases 5 dirty pump valves Inspect valve units Clean or replace the components if necessary 6 Oil leaks through the filler and drain caps Loose caps or damaged gaskets to be replaced 7 Damaged piston seal gasket Air inlet in oil chamber through piston seals Scratched piston Replace the...

Страница 8: ...equested The pumped liquid is mixed with hydraulic chamber oil The diaphragm is broken Assess the state of the components if damaged Replace the diaphragm and any OR the oil chamber the piston the seal gaskets Run the filling procedure HEAD DISASSEMBLY AND DIAPHRAGM REPLACEMENT In this pump model the head is directly blocked on the oil chamber therefore the oil contained in the chamber must be dra...

Страница 9: ... taking care to tighten the two dowels with the same force so that the piston is coaxial with the slide FILLING OF OIL CHAMBER Once the maintenance operations are complete and the head components reassembled fill the oil chamber The following tables feature some brands and necessary quantities For proper operation proceed as follows Turn the adjusting knob clockwise to bring the piston to FDC at 0...

Страница 10: ...2 Mobil DTE 24 Before starting the pump the operator must check that the plant shut off valves previously closed for maintenance are opened ROUTINE MAINTENANCE ref UNI 11063 The table shows the parts subject to greater wear which therefore require routine maintenance We recommend verification and replacement if necessary Components to be checked Maintenance period Oil chamber Head Valve unit Hydra...

Страница 11: ...DOSEURO XMPE0TMB125SST014 11 12 1st Edition 2014 NOTES ...

Страница 12: ...IES Request them to our Sales Department Doseuro S r l The Right Dosing Choice Via G Carducci 141 20093 Cologno Monzese Mi Italy Tel 39 0227301324 Fax 39 0226700883 http www doseuro com e mail info doseuro it ETA Ekipman Teknoloji Ar Sis San Tic Ltd Şti www etaekipman com blog etaekipman com Tel 0 216 540 99 64 Fax 0 216 540 99 68 ...

Отзывы: