![dosatron D8RE3000 Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/dosatron/d8re3000/d8re3000_troubleshooting-manual_2523980009.webp)
Page 9
1-800-523-8499 • www.dosatronusa.com
Proper protection, such as gloves, eyewear, and aprons, are recommended when disassembling a Dosatron.
D8RE3000 Troubleshooting - Part 3
Step 3:
Grasp the white plastic bridge on top of the piston and pull
it straight out.
Step 2:
Use the strap wrench (Part #: TOOL01) to loosen the bell
housing. Unscrew, remove and set it aside.
If the Dosatron injector is not clicking or is stalling at low
flow, we need to investigate the piston.
Step 1:
Turn the water off and press the air bleed button a few
times to release the pressure.
This D8RE3000 - 40 GPM Troubleshooting Part 3 will cover: The injector is not clicking
or is stalling at low flow.