Symptom Cause 

Solution 

                        Dosing 

 

No suction of solution (cont.)

 

Worn, scratched/scored piston shell and/or 
body  

Do piston “fit” test (see instructions). If neces-
sary replace piston shell and/or body. Make 
sure your installation has a 200 mesh filter 
before the Dosatron.  

Suction of air  

Check suction tube connection. Inspect      
suction tube for pin holes or cracks.  
Check tightness of connection nuts.  
Cut ½” off top of the hose and reattach it   
correctly.  

Excessive water flow  

Listen to the unit clicking, count the  
individual clicks, should not exceed 46 clicks 
in 15 seconds otherwise is  
excessive flow. If excessive flow reduce the 
flow rate and restart the unit slowly.  

Worn plunger seal  

Replace plunger seal.  

Worn or cracked injection stem (inside and 
outside)     .  

Replace injection stem.  

Check valve worn, improperly assembled, 
dirty or damaged  

Clean or replace check valve assembly. Be 
sure the check valve seal is in proper position. 

                     Leaks 

 

 Leaks near the metal collar 
under the body.  

Sleeve O-ring damaged, improperly posi-
tioned or missing  

Replace sleeve O-ring.  

Leaks between adjusting nut 
and the anti-lock ring.  

Dosing stem O-ring damaged, improperly 
positioned or missing  

Clean and replace dosing stem O-ring.  

Leaks between body and lid.   Lid O-ring damaged, improperly positioned 

or missing  

Clean the seating surface of the O-ring and 
position O-ring correctly or replace the lid     O
-ring.  

Troubleshooting for D25 Series  