Requirements for the
Installation point.
The compressed air supply to the spray
gun must be interrupted and secured
against reconnection.
The compressed air supply must be
adjustable.
Lines, seals and screw connections must
be designed to conform to the require-
data”.
The workplace must have a mechanical
ventilation.
A hook or a lug must be provided for
hanging the spray gun.
Working environment and grounding
The flooring of the working area must be
anti-static according to DIN EN
50050-1:2014-03, measurement according
to DIN EN 1081:1998-04. The antistatic
flooring prevents electrostatic charges from
building up. Dangerous flashovers are pre-
vented.
4.2
Connecting
Personnel:
Operator
+ additional qualification high tension
technology
+ additional qualification explosion pro-
tection
Protective equipment:
Protective workwear
Anti-Static Safety Boots
1.
WARNING!
Sources of ignition may cause explo-
sions!
Ensure a non-explosive atmosphere.
Fig. 2: Connect compressed air supply
2. Bolt compressed air supply (3) to the
compressed air controller (2) of the elec-
trostatic controller (1).
Fig. 3: Ground electrostatic controller
3. Screw on grounding cable (5) to the
grounding bolt (4) of the electrostatic con-
troller (1). Connect with the grounding
point at the installation site.
Assembly
11/2019
EcoGun AS MAN DC - MSG00023EN
8/56