7.5.6
Replacing the contact ring
The contact ring is bolted to the color tube with three screws.
The turbine must be dismantled in order to remove the contact ring.
7.5.6.1
Dismantling the contact ring
• Release the three screws on the contact ring and remove the
contact ring.
Fig. 159: Screws on the contact ring
1
Screws
7.5.6.2
Installing the contact ring
For the assembly of the contact ring there is a centering sleeve. The
contact ring must be centered on the flange of the color tube with the
centering sleeve. Only when the contact ring is in the correct position,
the three screws must be used and tightened.
Fig. 260: Placing the centering sleeve
• Push centering sleeve over the paint tube.