20
6.5.2 Heartbeat
Heartbeat
is a way to monitor the Doro Eliza’s function, enable remote configuration and
FOTA. If set to
“Disabled”, the Doro Eliza will turn off this feature. Heartbeat is used with the
ICO platform.
Value: Disabled or 1-20 minutes, Default=2 minutes
Note! If Heart
beat is disabled it won’t be possible to remote access from the ICO platform.
6.6 Inactivity alarm
Inactivity alarm is a function that is used for sending an alarm (alarm type 14) if no activity
occurs during a certain pre-configured time. When inactivity alarm is activated an internal
timer starts that generates an alarm if it is not reset within the set time. After every reset the
timer will restart.
The inactivity alarm is cleared, and the time will be recounted from the start at the following
events:
Example; expecting certain activity of the client during the day makes this function work as a
check to ensure the well-being of the client.
•
The Cancel
button is used for resetting the inactivity alarm manually.
•
Activation of a programmed radio trigger/accessory. If the trigger is configured to
transmit alarm type 12 (reset) the Eliza´s alarm function will not be activated.
•
AUX can be used for resetting the activity alarm by wire connecting a fixed trigger,
sending alarm type 12.
If the function pre-alert for inactivity alarm is activated, the Doro Eliza will (through an audible
signal once every minute during the set time) alert the user that the time for inactivity alarm is
about to expire
.