background image

 

         

      

 

  DECT 4055

Caller display compatible 

digital cordless phone

 

This equipment is not designed for making emergency telephone calls when the power fails.

Alternative arrangements should be made for access to the emergency services.

User guide

Содержание DECT 4055

Страница 1: ...isplay compatible digital cordless phone This equipment is not designed for making emergency telephone calls when the power fails Alternative arrangements should be made for access to the emergency se...

Страница 2: ...ging 23 Ring count 23 Use 8 PABX usage 24 Standby mode 8 Emergency number 25 Answering incoming calls 8 Call barring 25 26 Do not disturb 8 Least cost routing 27 Making an external call 8 PIN code 28...

Страница 3: ...rging contacts 2 Earpiece 11 Microphone 3 Display 12 On Off button 4 Talk button 13 Mute Cancel button 5 Scroll button UP 14 Programming button 6 Keypad button 0 9 15 Scroll button DOWN 7 Recall butto...

Страница 4: ...tor 19 Line cord socket 22 Charge indicator 20 Charging contacts 23 Paging button UNPACKING In the box you should find the following items n Handset n Power supply n Base unit n Line cord n 2 NiMh bat...

Страница 5: ...s n Do not locate close to electrical equipment such as TV s computers fridges etc or close to radiators metal pipes or window frames GETTING CONNECTED n Remove the battery cover from the bottom of th...

Страница 6: ...urs n The rechargeable batteries NiMH are cadmium free and should be disposed of in a responsible and environmentally friendly manner IMPORTANT From new the batteries supplied must be charged for 8 ho...

Страница 7: ...gular holes on the sides RANGE WARNING If you are on a call and accidentally walk out of range of the base unit the sound quality in the earpiece will de grade and warning beeps will be heard IN USE T...

Страница 8: ...when the handset is out of range of the base unit Programming is on when programming External call is on when an external call is in progress flashes when an external call is received Internal call is...

Страница 9: ...be programmed to connect with a call automatically when lifted off the base unit if required see page 18 DO NOT DISTURB If you receive an incoming call but do not want to be disturbed press and releas...

Страница 10: ...rhearing press the button the mute symbol will appear on the display To resume the conversation press the button again PAGE FIND HANDSET To page or locate a missing handset press the button on the bas...

Страница 11: ...the number you which to store max 20 digits n Press the button n Continue to store other numbers or press the button to finish If you insert an incorrect digit you can erase it by pressing the C butt...

Страница 12: ...utomatically It is not possible to view the call list and take a new call at the same time WARNING Caller display is an optional telephone Network service This telephone will provide Caller Display in...

Страница 13: ...equence number which appears on the left hand side of the display commencing with 01 oldest call up to 39 latest call 1 Press and hold the button until the display shows the number of new calls and th...

Страница 14: ...number The list has been reviewed to the latest number Call information is not available It could be an international call The caller has withheld their number or the number cannot be transmitted Ther...

Страница 15: ...rASE ALL then release n Press the C button again all phone numbers will be erased IF THE LIST IS FULL Up to 39 incoming numbers can be stored in the call list including Ou t oF arEa and SecrEt informa...

Страница 16: ...the menu system and confirm a setting The button can be used to revert back to standby mode without saving The C button is used to erase THE MENU CONSISTS OF TWO MAIN GROUPS Handset menu Used to set t...

Страница 17: ...desired setting with and buttons n Press to store your setting In order to hear the correct setting while programming the key beep must be activated HANDSET RINGER MELODY BELL TYPE You can choose from...

Страница 18: ...P Press n The display shows the current setting on or oFF n Scroll to desired setting with or buttons n Press to store the setting HANDSET KEYPAD SOUND BEEP From new the handset keypad is programmed t...

Страница 19: ...feature enables the handset to be pre programmed with an emergency number which can be dialled automatically by pressing any button except the programming button It is possible to answer calls even if...

Страница 20: ...SELECT A BASE UNIT SELECT BS If the handset is registered to more than one base unit you can select one base unit as a special base unit irrespective of how many base units are registered n Press foll...

Страница 21: ...andset is added to the system it must be registered to the base unit P Press and hold the on the base unit until you hear a series of beeps then release approximately 4 seconds You now have 30 seconds...

Страница 22: ...0000 from new n Press to confirm RESET ALL SETTINGS DEFAULT SET If this operation is performed all factory settings will be restored Handsets PIN code restored to 0000 Keypad beep on Ring signal level...

Страница 23: ...f low normal and high for the base unit ringer n Press followed by n Scroll until the display shows bELL Lou d Press n The display shows the current setting oFF off 3 highest level n Scroll to desired...

Страница 24: ...ber n Enter desired handset identity number by pressing on the keypad digit If you choose 0 all handsets will ring n Press to store the setting RING COUNT RING COUNT When a handset has been prioritise...

Страница 25: ...The secondary access code is identified as S CODE0 S CODE1 S CODE2 n Press followed by n Scroll until the display shows AccESS codES Press n The display will show on of the six setting n Scroll to des...

Страница 26: ...ll buttons n Enter the phone number with the keypad digits max 12 digit If you enter an incorrect digit press the C button to erase n Press to store the setting CALL BARRING CALL BLOC Call barring can...

Страница 27: ...the setting SET BLOCK NUMBER SET BLOC NO The base unit can bar up to 3 numbers of the 8 digits restrict outgoing calls n Press followed by n Scroll until the display shows SEt bLoc no Press n Enter th...

Страница 28: ...an access code Up to two access codes can be stored under either position L code0 00 or L code1 PROGRAMMING LEAST COST ROUTING n Press followed by n Scroll until the display shows Lcr SEt Press n Ent...

Страница 29: ...t no 1 n Press followed by n Scroll until the display shows dE rEg Press n Enter the base units PIN code 0000 form new n Press the corresponding keypad digit of the handset you which to deregister n P...

Страница 30: ...Profile compatible handset to the base unit ADDITIONAL BASE UNITS By connecting several base units to one system the range of each handset can be extended but it is critical that all base units are w...

Страница 31: ...d at the same time If an additional handset is added to the system the batteries must be charged for 8 hours without interruption The registration procedure see page 20 must be performed prior to use...

Страница 32: ...r a Press the R The internal call will be terminated or b Press the INT button to place the internal call on hold and answer the incoming call You can switch between an external call and an internal c...

Страница 33: ...f equipment and ensure that the power line cords are separated from other electrical units FAULT FINDING THE IN USE LINE INDICATOR ON THE BASE UNIT IS FLASHING n There is new phone number in the calle...

Страница 34: ...nd mains power switched on THE DISPLAY ON THE HANDSET IS BLANK P Is the handset switched off P Is mains power switched on THE BASE UNIT RINGS BEFORE THE HANDSET P This is normal for all cordless telep...

Страница 35: ...ices numbers The power supply output and the handset charger contacts are SELV circuits as defined in EN 41003 The equipment has been approved in accordance with Council Decision 98 482 EC for pan Eur...

Страница 36: ...00 metres in ideal conditions Indirect memory 10 numbers Caller display memory 39 numbers Battery 2 x 1 2V AA NiMH type Weight Handset 170 gm Base unit 200 gm Size B x H x D Handset 45 x 155 x 26 mm B...

Отзывы: