![Dorna 110DNA-04C Скачать руководство пользователя страница 33](http://html.mh-extra.com/html/dorna/110dna-04c/110dna-04c_user-manual_2523065033.webp)
33
6.1.8 Other function parameters
param
eter
code
parameter Name & functions
Set range
unit
Default
value
Effective
PA063
Stop mode after servo OFF
0
:
Motor decelerates to speed of PA61, then power off
after delay PA60;
1
:
Motor coast to stop.
0~1
1
PA061
Motor speed at mechanical brake
When motor speed is lower than this set value,
BRK_OFF signal invalid.
0~100
rpm
10
PA060
Power off delay time after servo Off
After S_ON signal is invalid, motor power will be off
after delay of PA060
0~9000
ms
150
PA053
Position deviation over-large alarm threshold
To set motor position deviation over-large detection
level, unit is 0.01r. Relevant pulse number is related to
encoder resolution.
0~500
0.01 r
300
PA054
Position deviation over-large alarm invalid
0~1
0
PA111
Stall alarm threshold
0~9000
0.1rpm
3000
PA112
Stall alarm time
0~9000
0.1ms
30
PA119
Over-speed alarm threshold
50~300
%
150
PA081
Over-load alarm threshold 1
0~300
%
130
PA082
Over-load alarm time 1
0~9000
ms
3000
PA120
Over-load alarm threshold 2
0~300
%
150
PA121
Over-load alarm time 2
0~9000
ms
1000
PA122
Over-load alarm threshold 3
0~300
%
180
PA123
Over-load alarm time 3
0~9000
ms
500
PA151
Brake loop release duty cycle
0~80
%
10
PA153
Control loop under-voltage alarm delay time
1~2000
ms
40
PA154
Control loop under-voltage alarm delay time
threshold
0~2000
0.5ms
75
PA139
Power off save parameter 1
0~249
0
PA140
Power off save parameter 2
0~249
1
PA005
Analog output signal deviation
When Output is speed, unit is rpm;
When output is torque, unit is percentage.
0~9000
0
PA007
Analog Output monitor selection
0
:
Motor speed
1
:
Motor Torque
0~1
0
PA008
Analog Output signal proportion coefficient
1~300
100