Series RFID Concierge Installation Guide - PK3673_T_07_16
*Important*
Review your local Fire, Electrical, and Building codes before installing this product. The installer must be capable and
knowledgeable of electrical access control systems. There are many variations of access control systems and local
codes; for this reason, the SR RFID Concierge kit must be installed by a qualified installer.
• HH6 firmware revision 1.32 or greater is required.
• MT4 firmware version 11-12-14 or greater is required.
Hardware
The concierge solution requires that all connections to the mortise must be routed through the door. This requires
additional hardware (hinge side power transfer) and cabling that is not part of the SR RFID Concierge kit. It is the
integrators responsibility to procure all additional hardware, cabling and instructions necessary to complete the job
and ensure these components meet any and all local standard or codes.
Power
A power source of 12-24V AC/DC with a minimum current of 125mA is required and not included with the kit. It is the
responsibility of the installer to ensure a proper low voltage power source is available to the SR Concierge Controller.
Location
The SR Concierge RFID reader should be located in close proximity to the access opening as the user will have
approximately 5 seconds to open the door before it relocks. The SR Concierge controller box must be within 15
meters of reader and mortise.
Messenger
For concierge equipped with the Messenger transceiver module the faceplate and electrical enclosure must be plas-
tic to ensure optimum transmissions of the RF communications to a nearby Messenger hub (SR Concierge controller
box faceplates are available in white, ivory, black, or dark brown plastic). If the controller location has not been
previously confirmed for connectivity to the Messenger network, consult the Messenger Site Survey instructions. In
some cases an additional hub may be required to ensure connectivity in new location.
Cable
It is recommended to run the wires from the controller to the SR reader and mortise using 3 twisted pair x 22 AWG
CMP cable (Belden 6542FE, or equivalent). Ensure any wire selected is compliant with all local standards and build-
ing codes.
Door Preparation
The two following illustrations indicate the required door prep for the mortise and wire routing to the mortise
pocket. 1:1 scale installation templates can be provided upon request.
Installation Requirements