Initializing the Reader

1.  When reader is powered for the first time, it must be initialized.
2.  Until initialized, the LED’s (9321only) will be flashing on and off. 

The sounder (9323 only) will beep 3 times per second.

3.  Take Enrolment Card you wish to enroll from Wallet.
4.  Present the Enrolment Card to reader(s).
5.  The LED’s (9321only) stops flashing.  

The (9323 only) stops beeping.

6.  All cards in Wallet are now valid; as such Wallet with 

programming cards and user cards must be stored in secure 

location to maintain proper building security.

Issuing Tokens

1.  On each page of Wallet, there are 2 ‘pairs’ of opposing cards.  

A ‘User Card’ and a corresponding ‘Deletion Card’. 

Do not mix up these pairs.

2.  Write users name on the Deletion Card.
3.  Take corresponding User Card from opposing pouch and  

issue to user.

Deleting a User (Barring)

1.  When token (card or fob) becomes lost or stolen, it is important 

to delete missing token from your system to avoid unauthorized 

access.

2.  To delete user, take their corresponding Deletion Card from 

Wallet.

3.  Present Deletion Card to reader(s). This will remove lost token 

(card or fob) from accessing your building.

4.  Should deleted user token (card or fob) becomes found, system 

administrator can re-enroll token.  

See “To Re-Enroll a Deleted User” below.

To Re-Enroll a Deleted User

1.  System administrator can re-validate token (card or fob).
2.  Present Enrolment Card to reader(s).
3.  Present user’s deleted token (card or fob) to reader(s).
4.  User’s token (card or fob) will now be valid again.

Setting “Door Open” Time

1.  Take Door Open Time function card from the Wallet.
2.  Present card to reader(s).  

Reader will begin beeping once per second.

3.  Wait for desired period of time you wish door to remain unlocked.
4.  Present Door Open function card again at end of that period to 

set unlock time. Beeping will stop. 

Silent Operation Card

1.  Take Silent Operation function card from Wallet.
2.  Present card to reader(s). Reader will beep.
3.  Switch 2 control unit is now in silent operation mode.
4.  Present card again to disable silent operation mode.   

Reader will beep.

To Enroll another Card Pack

1.  Additional Card Pack(s) may be added as needed.
2.  To enroll an additional Card Pack, first present the Enrolment 

Card from any currently enrolled Card Pack to reader.

3.  Follow this by presenting the Enrollment Card from new  

Card Pack.

4.  New Card Pack is now enrolled.

Hardwire Reset Instructions

The proximity reader will remember its settings and details of card 

validity in the event of a power failure. A data reset may be carried 

out to return the unit to its factory settings.  

The procedure for doing this is as follows:
1.  Turn off the power to the control board.
2.  Disconnect the Green and Mauve wires from the Prox Reader at 

the Switch 2 control unit (9321only).

3.  Insert a wire jumper between the Green and Mauve terminals (not 

supplied).

4.  Turn on power and switch 2 control unit. It will beep four times.
5.  Turn off the power and remove the wire jumper.
6.  Reconnect the Green and Mauve wires to their appropriate 

terminals (9321 only).

7.  Re-apply power. The reader has now been reverted back to 

factory settings. 

“Door Open” time = 7 seconds / no tokens valid

Troubleshooting

Programming Instructions

The reader operates with a Wallet of cards which contains:  

an Enrollment Card, Fail Open Release Card, Silent Operation Card, Door Open Card, 10 Deletion Cards and 10 User Tokens (Cards or Fobs).  

Card/Fob packs are sold separately.

Problem

Solution

Door Open Time (DOT) 

card not accepted by 

reader

- Present the enrollment card to the reader 

- Present the DOT card to the reader

- DOT card should now be accepted

Tokens (cards or fobs) 

not being accepted by the 

reader

- Present the enrollment card to the reader
- Present the token to the reader
- Tokens should now be accepted

Second Wallet  

(enrollment card) not  

being accepted by the 

reader

Additional Wallets can only be added to the 

reader by first presenting any one of the 

currently enrolled enrollment card(s) followed 

by the new Wallet enrollment card(s)

Содержание READ-PROX RCI 9321

Страница 1: ...t wall with LED s at bottom mark position of three mounting holes 6 Drill the three mounting holes as appropriate for the type of fasteners being used 7 Install level the reader and secure with three mounting screws 8 Install removable cover by engaging top tab and pivoting cover down over reader Cover should snap in place when installed properly 9 Cover is secured with single screw provided on lo...

Страница 2: ...er to control board as shown in Fig 5 If additional reader is required for in out operation wire the reader in parallel 5 Reader operates on 12VDC only Connect reader to power transformer and electric lock as shown in Fig 6 or Fig 7 Note Unit requires a filtered and regulated power source for proper operation See our line of power supplies and transformers for options to use Fig 3 Fig 4 Micro Read...

Страница 3: ...Canada Inc www dormakaba us Phone 1 800 265 6630 Fax 1 800 482 9795 E mail sales_RCI dormakaba com Fig 7 Proximity MicroReader Red Fig 6 Proximity Micro Reader or or Proximity Slimline Reader Proximity Slimline Reader ...

Страница 4: ...ard 1 Take Silent Operation function card from Wallet 2 Present card to reader s Reader will beep 3 Switch 2 control unit is now in silent operation mode 4 Present card again to disable silent operation mode Reader will beep To Enroll another Card Pack 1 Additional Card Pack s may be added as needed 2 To enroll an additional Card Pack first present the Enrolment Card from any currently enrolled Ca...

Отзывы: