Page 2
1.
DESCRIPTION
The RD10 is a low voltage motor driven lock suited for securing large rolling, tilting, hinged or sliding doors and
shutters. It is supplied with a matching strike plate and can be installed internally in a horizontal or vertical position.
A solid 18mm diameter stainless steel bolt pin ensures the highest strength while a bolt pin extension of 35mm offers
flexible installation.
Integrated electronics provide complete control over the lock and offer an array of features;
▪
Multi
–voltage input (12-24VDC)
▪
Multiple locking / unlocking attempts to correct miss-aligned doors
▪
Selectable automatic locking when the door closes
▪
Fail safe / Fail secure user selection with a single switch
▪
Door position monitoring
▪
Bolt locked and Bolt unlocked monitors
The lock incorporates a keyed manual override and wiring can be run securely through the locks base or externally
through a 20mm wiring gland.
2. PRODUCT UNBOXED
Lock Cover with two keys
Lock
Lock Mounting Bolts Strike
Because of the various fitting locations of the RD10,
no mounting bolts are supplied for the strike.
The mounting
holes in the strike are 8.5mm slotted holes so accept M8 size bolts.
3. PRE - INSTALLATION ASSESMENT
3.1 Mechanical
Before the lock can be installed, consider its location and orientation. The lock is commonly placed on the ground
and secured using the
supplied
mounting bolts; however it can readily be mounted to a wall by choosing the
appropriate bolts / screws
(not supplied)
. The strike will be fitted to the door again by selecting and using the
appropriate bolts / screws
(not supplied)
.
When positioning the strike, it is important to achieve a reasonable level of alignment with the bolt pin as to ensure
correct locking and operation. The hole in the strike is of significantly larger diameter than that of the lock pin, however
installing the strike so the lock pin goes into the hole centrally is best as it will allow for movement of the door over
time.