Dormakaba RCI ILO6KT Скачать руководство пользователя страница 3

3

Function 

#1:  Barrier Free Washroom Control 

c/w 

Emergency Call Function

Operational 

Description:

 Door is normally closed and unlocked

Entry by Exterior Push to Open (PTO) 

button activates the Auto-Operator and allows entry 

or manual means.

Activating the Interior Push to Lock (PTL) button locks the door, deactivates the exterior  PTO 

button & activates exterior Occupied Light

Egress can be by Interior PTO 

button or manually 

opening 

the door.

System is reset by PTO 

button and door contact.

Interior Emergen

cy Button unloc

ks the door and activates an interior and exterior audible 

and visual alert.

Resetting is by manual means.

+12VDC

0V

DRY 

1

INPUT

DRY 

2

INPUT

DRY 

3

INPUT

DRY 

4

INPUT

DRY 

5

INPUT

DRY 

6

INPUT

N/O

CO

M

N/C

N/O

CO

M

N/C

N/O

CO

M

N/C

N/O

CO

M

N/C

N/O

CO

M

N/C

N/O

CO

M

N/C

POWER 12VDC

+‐

EXTERIOR  PUSH TO OPEN

COM

N/O

DOOR CONTACT

COM

N/O

PUSH TO LOCK

COM

N/O

INTERIOR PUSH TO OPEN

COM

N/O

EMERGENCY CALL

COM

N/O

ELECTRIC STRIKE ‐ FAIL SAFE

+

AUTO OPERATOR

IN 2

IN 1

OCCUPIED (O) / VACANT (V) LIGHT

+ O

+ V

EMERGENCY CALL LIGHT & SOUNDER

+

JUMPER 1 

*

*

**

JUMPER 2

*

*

OUT 4

ILO6 ‐ FUNCTION 1

R/

T

IN 1

IN 2

IN 3

IN 4

OUT 5

OUT 6

IN 5

IN 6

OUT 1

OUT 2

OUT 3

IN THE EVENT OF 

AN 

EMERGENCY

 PUSH 

EMERGENCY

 BUTT

ON 

AND AUDIBLE AND 

VISUAL

 

SIGNAL

 WILL

 ACTIV

ATE