Dormakaba PT30 Скачать руководство пользователя страница 3

dormakaba Universal Patch Fittings PT30  
Installation Instructions

833002

07-2019

Universal Patch Fittings

3

Technical specifications

1   Technical specifications

1.1 Overview

These instructions are for installation of the Universal 
PT30 Overpanel Patch Fittings for the following 
mounting and style versions:

1.  Glass mounting

1.1.1

 

General information

• 

dormakaba requires use of tempered monolithic 
glass.

• 

dormakaba glass hardware is not suitable for harsh 
environment; for example, applications where 
chemicals (e.g. chlorine) are used such as indoor 
swimming pools, saunas, or salt-water pools.

• 

Do not swing doors with excessive force. Install 
limiting stop to prevent door from opening too far.

1.1.2

 

Intended use

• 

For pivoting doors in indoor or covered areas only.

• 

For manual slowly opening and closing only.

1.1.3

 

Glass requirements/fittings/mounting

• 

The substructure/wall must be able to bear 
permanent loads, and be level (max. tolerance: 
1/16” [2] per 39” [1m]).

• 

Fasteners must be sufficiently dimensioned for the 
substructure/wall and weight of the door.

• 

When adjusting glass elements, always stick to the 
required clearance for the respective hardware. 
Adjust clearance so glass does not come in contact 
with any hard surfaces such as glass, metal or 
concrete.

• 

Do not use excessive force when installing the glass 
(avoid over tightening screws.)

1.1.4

 

Requirements for glass panel

• 

dormakaba requires use of fully tempered glass, 
which complies with ASTM C 1036 and ASTM C 
1048. Secondary heat soaking processes are 
optional but not required. 

• 

Clamping area must be flat and uncoated (no 
self-cleaning coating!)

• 

Never use glass with conchoidal fractures and/or 
damaged edges.

1.1.5

 

Safety instructions

• 

Installation requires two people.

• 

Always wear protective clothing.

• 

Only properly qualified and specially trained staff 
are authorized to mount dormakaba glass 
hardware.

• 

Due to crushing hazards and possible injury caused 
by breakage of glass during mounting, 
corresponding protective clothing (especially gloves 
and protective goggles) is required.

• 

Never clamp metal fitting hardware directly to 
glass surface.

1.1.6

 

Symbols used - Safety/Installation

CAUTION

Mounting components must meet the 
requirements of substructure/wall and door 
weight. Please read the technical information 
for fittings.

WARNING

Risk of breaking glass. When installing the 
door, support the door panel with a block of 
wood or similar object.

CLOSING EDGE OF DOOR

1.1.7

 

Maintenance, care, repair

• 

Immediately replace damaged parts.

• 

Always use original dormakaba parts.

• 

Clean clamping area with alcohol-based standard 
commercial cleaning agent before mounting the 
glass hardware.

• 

Use a damp cloth for occasional cleaning.

• 

Always use silicone - and oil-free cleaners (e.g. 
acetone).

• 

Check glass hardware at regular intervals for 
proper positioning, smooth operation and correct 
adjustment.

• 

High traffic door systems require inspection by 
properly qualified staff (specialized companies or 
installation firms.)

• 

Function of fittings is recommended to be 
inspected every 500,000 movements by a specialist.

1.1.8

 Disposal

Disposal in accordance with local, state and national 
regulations.

Содержание PT30

Страница 1: ...Universal Patch Fittings PT30 Overpanel Installation instructions 833002 07 2019 EN ...

Страница 2: ...Glass requirements fittings mounting 3 1 1 4 Requirements for glass panel 3 1 1 5 Safety instructions 3 1 1 6 Symbols used Safety Installation 3 1 1 7 Maintenance care repair 3 1 1 8 Disposal 3 1 2 Door dimensions options 4 2 Installation instructions 5 2 1 Overall 5 2 2 Install the gaskets 5 2 3 Secure wall plate to fitting 6 2 4 Install fittings on glass 6 2 5 Install inserts 6 2 6 Install door ...

Страница 3: ...C 1048 Secondary heat soaking processes are optional but not required Clamping area must be flat and uncoated no self cleaning coating Never use glass with conchoidal fractures and or damaged edges 1 1 5 Safety instructions Installation requires two people Always wear protective clothing Only properly qualified and specially trained staff are authorized to mount dormakaba glass hardware Due to cru...

Страница 4: ...Installation Instructions 833002 07 2019 Universal Patch Fittings 4 Technical specifications 1 2 Door dimensions options PT30 with Pivot PT30 with Stop PT30 with Blank Pivot Stop Blank PT30 PT20 PT10 BTS PT30 PT20 PT10 BTS PT30 PT20 PT10 BTS ...

Страница 5: ...dent 2 5 Insert fasteners 2x included 2 6 Patch fasteners 3x included 2 7 Glass grommets 1x included 2 2 1 If have 1 2 13 or 3 4 19 glass Fittings will come with 2mm 3 32 glass gaskets pre secured 2 1 2 7 2 6 2 4 2 3 2 2 2 5 2 6 2 1 2 2 2 3 2 2 2 If have 3 8 9 or 5 8 15 glass Fittings will come with 2mm 3 32 glass gaskets pre secured PLUS additional 2 3mm 1 8 glass gaskets Remove 2mm gaskets and r...

Страница 6: ...ew 2 5 3 Place pivot insert into top of PT20 Fittings 2 4 4 Temporarily support transom to mark wall plate location 2 4 5 Lift and secure transom to ceiling frame surface using product appropriate to transom weight and height 2 4 6 Secure wall plate with two included fasteners 2 4 7 Tighten and torque fitting Torque value Fittings 10 ft lbs 15Nm 2 5 Install inserts Fig 5 2 3 4 70 from wall sidelig...

Страница 7: ...rt PT30 M6x16 2 7 1 Aligh hole in cover with spring pin on end of fitting 2 7 2 Snap covers onto patch fittings 2 7 3 To remove Depress spring pin and pop cover off 2 7 Install covers Fig 7 PT20 PT30 PT10 Floor pivot spindle 2 6 1 Place bottom patch fitting onto floor pivot spindle 2 6 2 Tip glass panel up and align PT30 pivot insert with PT30 patch fitting 2 6 3 Secure insert with included M6x16 ...

Страница 8: ...www dormakaba com dormakaba DORMA USA Inc 1 Dorma Drive Drawer AC Reamstown PA 17567 USA T 717 336 3881 F 717 336 2106 ...