Страница 1: ...Universal Patch Fittings PT30 Overpanel Installation instructions 833002 07 2019 EN ...
Страница 2: ...Glass requirements fittings mounting 3 1 1 4 Requirements for glass panel 3 1 1 5 Safety instructions 3 1 1 6 Symbols used Safety Installation 3 1 1 7 Maintenance care repair 3 1 1 8 Disposal 3 1 2 Door dimensions options 4 2 Installation instructions 5 2 1 Overall 5 2 2 Install the gaskets 5 2 3 Secure wall plate to fitting 6 2 4 Install fittings on glass 6 2 5 Install inserts 6 2 6 Install door ...
Страница 3: ...C 1048 Secondary heat soaking processes are optional but not required Clamping area must be flat and uncoated no self cleaning coating Never use glass with conchoidal fractures and or damaged edges 1 1 5 Safety instructions Installation requires two people Always wear protective clothing Only properly qualified and specially trained staff are authorized to mount dormakaba glass hardware Due to cru...
Страница 4: ...Installation Instructions 833002 07 2019 Universal Patch Fittings 4 Technical specifications 1 2 Door dimensions options PT30 with Pivot PT30 with Stop PT30 with Blank Pivot Stop Blank PT30 PT20 PT10 BTS PT30 PT20 PT10 BTS PT30 PT20 PT10 BTS ...
Страница 5: ...dent 2 5 Insert fasteners 2x included 2 6 Patch fasteners 3x included 2 7 Glass grommets 1x included 2 2 1 If have 1 2 13 or 3 4 19 glass Fittings will come with 2mm 3 32 glass gaskets pre secured 2 1 2 7 2 6 2 4 2 3 2 2 2 5 2 6 2 1 2 2 2 3 2 2 2 If have 3 8 9 or 5 8 15 glass Fittings will come with 2mm 3 32 glass gaskets pre secured PLUS additional 2 3mm 1 8 glass gaskets Remove 2mm gaskets and r...
Страница 6: ...ew 2 5 3 Place pivot insert into top of PT20 Fittings 2 4 4 Temporarily support transom to mark wall plate location 2 4 5 Lift and secure transom to ceiling frame surface using product appropriate to transom weight and height 2 4 6 Secure wall plate with two included fasteners 2 4 7 Tighten and torque fitting Torque value Fittings 10 ft lbs 15Nm 2 5 Install inserts Fig 5 2 3 4 70 from wall sidelig...
Страница 7: ...rt PT30 M6x16 2 7 1 Aligh hole in cover with spring pin on end of fitting 2 7 2 Snap covers onto patch fittings 2 7 3 To remove Depress spring pin and pop cover off 2 7 Install covers Fig 7 PT20 PT30 PT10 Floor pivot spindle 2 6 1 Place bottom patch fitting onto floor pivot spindle 2 6 2 Tip glass panel up and align PT30 pivot insert with PT30 patch fitting 2 6 3 Secure insert with included M6x16 ...
Страница 8: ...www dormakaba com dormakaba DORMA USA Inc 1 Dorma Drive Drawer AC Reamstown PA 17567 USA T 717 336 3881 F 717 336 2106 ...