1. ENABLE Z-WAVE JOIN MODE 

  •  Press the “Select” button on the front of the controller until the LED by the Z-Wave icon is 

blinking (approx. 3x).

  • Press the “Sync” Button. The Smart Controller will be in Z-Wave “Join” mode for 10 minutes.

2. JOIN Z-WAVE DEVICES

  •  Follow the instructions for the Z-Wave device to enable Z-Wave join/search mode.
  •  The Z-Wave device will indicate if it was successfully added to the Z-Wave network. This process 

can take from a few seconds to a few minutes.

  •  The Z-Wave device should be accessible in the BeHome247 website under the “Settings” tab.

1. Power

2. Internet

3. Wi-Fi

4. Z-wave

5. Service

6. ZigBee

7. Bluetooth

ORACODE SMART CONTROLLER DIAGNOSTICS
1.  LOCK TO SMART CONTROLLER “CONNECTION” STATUS

 • Entering # # # 2 on the lock keypad triggers a “Lock to Smart Controller” status test.
  •  A green LED and a high-pitched beep at the end of the test indicates the lock is connected to the Smart Controller.
  •  A red LED and a low-pitched beep at the end of the test indicates the lock is not connected to the Smart 

Controller.

2.   WIRELESS  LINK  TEST

  •  This test requires the Smart Controller to be put in ZigBee “Join” mode (by enabling “Join” on the BeHome247 

website) if the Lock is not already connected to the Gateway (see 18.1).

  •  Entering # # # 1 on the lock keypad triggers a “Lock to Gateway” wireless link test.
  •  The lock’s LEDs alternate green and red during the test, which may be very quick or last over 30 seconds (depending 

on if the lock is already connected to the Smart Controller network or not).

  • A green LED and a high-pitched beep at the end of the test indicates a good link quality (success).
  • A red LED and a low-pitched beep at the end of the test indicates a bad link (fail).
  •  If the Wireless Link Test fails, improve the Smart Controller positioning (see 16.1) and re-execute the Wireless Link 

Test.

3.  SMART CONTROLLER RESET TO FACTORY DEFAULT

 

NOTE: 

You will need to get a new Activation Code from the Oracode Live web site to re-activate the lock (see Point 

  17) after you perform a Reset to Factory Default of the Smart Controller.
 

METHOD 1

  •  Use a paperclip or pencil to press the “Reset” button (on the front of the Smart Controller) six times within six 

seconds. The Smart Controller will be reset to factory default.

  METHOD 2

  • Log into your BeHome247 account (vr.behome247.com).
  •  Select the property where the Smart Controller is installed, then click 

the “Settings” tab.

  •  Scroll down to the ‘KABA Lock System’ area, check the “Show 

advanced controls” box, and click “Reset.” The Smart Controller will be 
reset to factory default.

18

Select Sync

Reset

Smart Controller (Front)

Содержание ORACODE 480 Series

Страница 1: ...e 1 25mm hole to be on the center line of door thickness 4 Mortise door edge for dead bolt face plate 5 Drill 2 1 8 from both sides of the door to prevent unsightly damage For maximum security install reinforcing plate Door stop 2 1 3 Install long screws in door stop side Do not remove tape Do not remove tape Slot at the bottom The dead bolt is pre set at 2 3 4 70mm backset Proceed as illustrated ...

Страница 2: ... and should never be removed Right hand RH Left hand LH Install key cylinder 4 5 ASSEMBLE TAIL PIECE REMOVE INSIDE COVER ASSEMBLE OUTSIDE HOUSING Click in place Run cable through door and under the dead bolt Remove tape Run cable through inside trim back plate slot 6 7 8 INSTALL INSIDE TRIM ASSEMBLY INSTALL INSIDE COVER 9 10 Connect W1 to W2 Communication Connect V1 to V2 Power Use short 8 32 scre...

Страница 3: ... surpassed and the lock time is lost the green LED will blink twice after a valid code is entered and the red LED will blink twice after a code is refused This indicates that the time must be reset with the Maintenance Unit 2 RESET TO FACTORY DEFAULT NOTE You will need to reprogram the lock with a Maintenance Unit after you perform a Reset to Factory Default Perform the following steps to erase a ...

Страница 4: ...tton The Smart Controller will be in ZigBee Join mode for 10 mins and the ZigBee LED on the Smart Controller will be blinking On the lock keypad press and enter the 8 digit Activation Code to start the activation process The lock s green LED will blink once at the beginning of the activation process the activation process could last from a few secs to 2 mins A green LED and a high pitch beep indic...

Страница 5: ...LINK TEST This test requires the Smart Controller to be put in ZigBee Join mode by enabling Join on the BeHome247 website if the Lock is not already connected to the Gateway see 18 1 Entering 1 on the lock keypad triggers a Lock to Gateway wireless link test The lock s LEDs alternate green and red during the test which may be very quick or last over 30 seconds depending on if the lock is already c...

Отзывы: