dormakaba MUTO XL120 Ceiling Mount with Dormotion and Self-Close
Installation Instructions
MUTO Premium
06-2021
936013
17
Start/stop
Self-closing unit
2.17.1 Secure self-close hold open clamp to the end
stop furthest from latch [closing side].
•
Use two screws and tighten to 2.5 ft lbs (3Nm).
Self-close
hold open
clamp
End stop
2.17 Install self-close hold open clamp
Hex key size
XL120
4mm
Legend
Closing edge
of door
CORRECT
INCORRECT
2.16.1
Adjust HEIGHT of start/stop
pin, if necessary
:
•
Loosen hex screws.
•
Slide pin and plate up or
down.
Start/stop
pin
Start/stop
pin
2.16 Adjust start/stop pin height (if necessary)
CORRECT PIN HEIGHT/
ORIENTATION
Hex key size
Hex
screws
3 mm
Fig. 16
Fig. 17
DORMOTION
trigger
Hex
screw
Hex
screw