background image

3

MUTO Comfort / Premium

2020-03

dormakaba Montageanleitung

Mounting instructions

Product description

WN 058855 45532

3.5  Setting options for the locking device

ON 1 2

DIP switch 1 = 

OFF

 Sequential control active

 

‣ Sequential control active = The locking device 

can only be activated with the door in closed 
position.

DIP switch 1 = 

ON

 Sequential control inactive

 

‣ Sequential control inactive = The locking 

device can be activated regardless of door 
position.  
Important: Carry a hand-held transmitter.

DIP switch 2 = 

OFF

 Audible warning active

DIP switch 2 = 

ON

 Audible warning inactive

3.6  Device LED feedback

Various locking states are indicated by the device LED 
flashing:

The device LED flashing 
code

Meaning

Slow flashing

Teach-in mode

Rapid flashing

Reset

Once long, x times short
(depending on error type)

Error.
Internal defect. 
The device must be 
replaced.

2x long, 1x short

Test after power ON

3.7  Acoustic feedback/Warning thresholds

A low or empty battery is indicated by beeping when 
DIP switch 2 = 

OFF

 "Audible warning active" is set.

Warning threshold 1:

2 beeps = battery replacement is recommended.

Warning threshold 2:

6 beeps = battery replacement is required.
The locking device can only unlock and then becomes 
inoperative.
Removing the batteries resets the meter.
Therefore we recommend only removing the batteries
to replace them. Otherwise the meter will not reflect 
the true battery charge status.

3.8  Notes on radio operation

The frequencies used by the locking device are also 
used by other devices, so interference cannot be 
excluded. Structural conditions and environmental 
influences such as humidity impact the transmitter’s 
range.

Duty cycle

The duty cycle describes a legally regulated limitation 
of the transmission time of devices in the 868 MHz 
range.

 The maximum transmission time is 36 seconds/hour. 
When this limit is reached, all further transmissions 
are inhibited (see Chapter 7).

3.9  Behavior after voltage recovery

A test is performed after the batteries are inserted. 
If an error is detected, this is indicated by the device 
LED flashing (see Chapter 3.6). This is repeated 
continuously and the locking device does not function.

Содержание MUTO Comfort

Страница 1: ...nce manual for manual sliding doors 1 4 Documents storage This manual must be kept during the service life of the product and must be passed on with the product 2 Safety 2 1 Intended use Only use the locking device in indoor areas and prevent the effects of humidity dust and sun or other heat radiation Only load the locking device up to the specified power limit Overloading can lead to destruction...

Страница 2: ... Premium XL 80 150 Parts included 3 2 Technical data Radio frequency 868 3 MHz Typ free field range 100 m Power supply 4x 1 5 volt lithium battery type AAA Battery life approx 2 years at 10 operations per day Standby power consumption 100 μA Dimensions WxHxD 14 x 18 8 x 64 mm Temperature 10 C to 55 C Humidity max 90 RH non condensing 3 3 Variants Fig 3 With battery pack 3 4 Locking device structur...

Страница 3: ...beeping when DIP switch 2 OFF Audible warning active is set Warning threshold 1 2 beeps battery replacement is recommended Warning threshold 2 6 beeps battery replacement is required The locking device can only unlock and then becomes inoperative Removing the batteries resets the meter Therefore we recommend only removing the batteries to replace them Otherwise the meter will not reflect the true ...

Страница 4: ...r insert tighten the cable ties and cut off the protruding end 18 Insert the batteries observing the polarity Optional cable set Art 36 855 for the locking device function as a status indicator Fig 4 green 3 yellow 4 grey 5 locked NO External status display max 30 V 1 A unlocked NC C Cable colors for the optional cable set 5 Connect locking device to a transmitter Please read this section complete...

Страница 5: ...itter or wall switch If this is required briefly press the teach in button see Chapter 3 4 once 7 Reset programming To reset the programming delete the transmitter and receiver data locking device Procedure for transmitter and receiver locking device 1 Press the teach in button for more than 4 seconds The device LED flashes red slowly To cancel the reset briefly press the teach in button again The...

Страница 6: ...e replaced by the operator Dismantling is carried out in reverse order of the mounting instructions Please refer to the mounting instructions for your MUTO sliding door system Proceed as follows to replace the battery 1 Remove the end caps Fig 7 1 and the cover profile Fig 7 2 from the track Fig 7 1 2 Remove the end cap and the cover profile 2 Replace the batteries observing the polarity Fig 8 Rep...

Страница 7: ...ovisions of the listed EC Directive s and that the standards and or technical specifications referred to below have been applied Directive 2014 30 EU Electromagnetic Compatibility 2014 53 EU Radio Equipment 2011 65 EU RoHS The technical documentation is available from the Product Compliance Manager at product compliance dach dormakaba com Harmonized European standard national rule EN 300 220 1 V3 ...

Страница 8: ...Translation of the original document subject to change without notice DORMA Glas GmbH Max Planck Straße 33 45 32107 Bad Salzuflen Germany T 49 2333 793 0 F 49 2333 793 4950 www dormakaba com ...

Отзывы: