background image

dormakaba USA Inc. | Keypad Installation Guide 7033.0320

 

 

Specifications 

Batteries 

Standard Profile Keypad: 2 x 9V DC alkaline batteries (Eveready™ or Duracell™ strongly preferred) 
Low Profile Keypad: 1 x 9V DC alkaline batteries (Eveready™ or Duracell™ strongly preferred, for emergency 
access) 

Relay 

12V DC @ 20 mA Max input 

Environmental 

Operating & Storage Temperature Range: For UL compliance, this product was verified for operation at 32 – 
122 

°F (

0 – 50 

°

C) 

Relative Humidity Range: 0 – 95% non-condensing 

Safe Lock Models 

Keypad Models 701, 702, 703, 704 and 705 (Input Units Keypads) for use with High Security Lock Models 731 
(Deadbolt), 732 (Springbolt) and 733 (Swingbolt). 

Содержание LA GARD 701

Страница 1: ...dormakaba USA Inc Keypad Installation Guide 7033 0320 Keypad Installation Guide ...

Страница 2: ...ed Phillips head screws The screws provided come in two variants Metric M4 07 or US Customary Unit 8 32 3 If mounting a deadbolt or springbolt do the following Do not use the anti rotate device during this process as it will render the safe permanently locked a Run the safe lock cable through the cable holder and place the cable holder over the corresponding posts of the Keypad body b Press the sp...

Страница 3: ...ed onto the safe they can be connected to form a System Follow these steps to connect a safe lock to a Keypad 1 For single lock Systems do the following a Connect the cable from the Keypad into the ENT port If a Battery Box Alarm Box or AC power adapter is used plug the cable from any of those accessories into the safe lock BAT port as shown in the diagram below b Follow the on screen prompts for ...

Страница 4: ...o the following 1 Press the button located at the bottom of the battery pack The spring mechanism will partially eject the battery pack out of the housing 2 With the battery pack partially removed grab the tip of the battery pack and remove it from the Keypad For low profile Entries do the following 1 If backup emergency power is needed flip up the battery panel on the lower housing which will rel...

Страница 5: ... Eveready or Duracell strongly preferred for emergency access Relay 12V DC 20 mA Max input Environmental Operating Storage Temperature Range For UL compliance this product was verified for operation at 32 122 F 0 50 C Relative Humidity Range 0 95 non condensing Safe Lock Models Keypad Models 701 702 703 704 and 705 Input Units Keypads for use with High Security Lock Models 731 Deadbolt 732 Springb...

Отзывы: