MUXD 19" (B6L 19")
5. Maintenance
22
22
A - Primary side with a 500 mATT microfuse
To check or replace the fuse, open the housing of the volt-
age selector with a flat screwdriver.
Then pull out the fuse from the cover removed from the
voltage selector. Please use only permitted fuses. They are
available as an accessory under item No.
1900001797351
.
B - 3.15 AT microfuse on power supply unit module
Then remove the fuse from the fuse holder. Please use only
permitted fuses. They are available as an accessory under
item No.
1900001797316
.
The use of other fuses is not permissible..
C - 10 AT microfuse on power supply unit module
Then remove the fuse from the fuse holder. Please use only
permitted fuses. They are available as an accessory under
item No.
0005167633330
.
The use of other fuses is not permissible.
D - SMD fuse
1)
If the fuse needs to be replaced, there is a replacement fuse
on the TP4 basic card. The fuse can be re-ordered using
item No. 1900001797487 (Lifflefuse type 0454.002T,
2 AT).
The use of other fuses is not permissible.
1
1
Содержание B6L 19