Air supply and flue gas discharge
Instruction Manual DR-FC
27
is
•
The maximum permitted number of 45° or 90° bends is four.
c
Note
If you make use of horizontal piping, then this must slope towards the water
heater with a minimum of 5 mm per metre running length!
Table 3.6
Chimney configurations for concentric wall and roof
termination.
Dimension
(1)
1.
See
’Figure 3.4 Wall flue terminal’
’Figure 3.5 Roof flue terminal’
.
DR-FC 25
DR-FC 30
DR-FC 45
DR-FC 60
A
0-15 m
0-15 m
0-15 m
0-15 m
B
0-15 m
0-15 m
0-15 m
0-15 m
a + B
max. 15 m
max. 15 m
max. 15 m
max. 15 m