background image

   

360SLT2 SMARTLINK

TM

 TPMS Tablet User Manual (v1) 

 

 

Doran Mfg. LLC – 2851 Massachusetts Ave – Cincinnati, OH 45225 – 866-816-7233 – Doranmfg.com 

15 

 

 

5.

 

SPECIFICATIONS 

 

 
 
 
 
 
 

SLT2 TPMS Tablet Specifications 

Wireless 

Communication 

Wi-Fi (2.4G) 

2.4G 

Bluetooth (2.4G) 

2.4G 

RF (434.1MHz) 

434.1MHz 

LF (125kHz) 

125kHz 

Tablet 

 Information 

OS 

Android 7.1.2 

Storage 

8GB 

Camera 

5.0MP 

Touch panel 

Capacitive 

Display 

7" IPS 

Screen resolution 

1280x800 

Power Adapter 

100~240V 

Battery 

5000mAh 

Power consumption  <8W 
Working 
Temperature 

0~55 

℃ 

 

Storage 
Temperature 

-20~60 

℃ 

 

Dimensions 

250Lx130Wx23H mm 

Weight 

0.56 kg 

Connection 

 

USB (Type C) 
USB (OTG) 
Micro SD card 

Содержание SMARTLINK 360SLT2

Страница 1: ...MANUFACTURINGLLC Please Read This Manual Carefully Before Using This Product 360SLT2 SMARTLINKTM TPMS TABLET USER MANUAL ...

Страница 2: ... TABLET TO THE INTERNET 4 1 5 CONNECT TO A COMPUTER FOR FILE TRANSFER 4 2 FUNCTIONS AND APPLICATIONS 6 2 1 INTRODUCTION 6 3 FUNCTIONS AND APPLICATIONS 6 3 1 PROGRAMING A TRANSCEIVER 6 3 2 READ TIRE SENSOR DATA 8 3 2 1 READ ONE CLICK TRANSCEIVERS 9 3 2 2 READ INDIVIDUAL TIRE SENSOR 10 3 2 3 RECORD TIRE DATA 10 3 3 SAVED FILES 11 3 4 APP SETTINGS 12 3 5 YARDCHECK360 WEB PORTAL 12 4 FAQS AND TIPS 14 ...

Страница 3: ...s It can be used to program a transceiver configuration and also access current tire data on the transceiver and individual sensors The Doran 360SLT2 uses the Google Android operating system The 360SLT2 can be connected to a computer via a USB C connection so that users can download saved data for documentation and analysis 1 1 PACKING AND ACCESSORIES The product comes with the following component...

Страница 4: ...til the display turns on and the blue Doran logo appears The tablet will automatically shut off to conserve battery if it is not used for 30 minutes 1 4 CONNECT THE TABLET TO THE INTERNET To connect the tablet to the internet first click App Settings on the home screen Next hit Tablet Settings Click on the WLAN button browse for the Wi Fi network and connect If the network is password protected th...

Страница 5: ...Android System notification will appear Swipe down from the top notification bar and select the option below Select the Transfer Files radio button This will allow the computer to access the internal storage of the tablet The tablet will now be accessible on the computer it is connected to The folder named Doran TPMS Data will have all exported data ...

Страница 6: ...sensor data from transceivers LFA TPMS sensors or record truck tire data with LFA sensors SAVED FILES o Access saved data from recorded tire data APP SETTINGS o Access Android settings change the unit of measure checking for software updates and setting up an email account ACCESS WEB PORTAL o Access the YardCheck360 web portal Only for use with YardCheck360 products 3 FUNCTIONS AND APPLICATIONS 3 ...

Страница 7: ... for low pressure level 2 and 125 PSI for the high pressure alert To set the global baseline pressure the button is pressed and the newly desired values are entered Confirm the pressure levels by pressing the Confirm button and then the Send Data to Transceiver button is pressed to transfer the new settings and save the global baseline pressure to the transceiver To program a tire sensor the desir...

Страница 8: ...ammed tire and then tapping the DELETE button The SEND DATA TO TRANSCEIVER button has to be pressed to apply the change Pressing the RELOAD button will take the tablet back to the transceiver selection screen if programming another transceiver is required 3 2 READ TIRE SENSOR DATA After clicking the Read Tire Sensor Data on the home screen the user is presented with three different options ...

Страница 9: ...the Read One Click Transceivers button will bring up a list transceivers Once a transceiver is selected the tire data will be loaded Clicking on a tire will bring up the tire details The user can also add information such as a serial number position ID tread depth and photos After information is added simply press CONFIRM and then the Save button to save the data to the tablet ...

Страница 10: ...d the tablet close to the sensor no more than 6 inches and press the READ INDIVIDUAL TIRE SENSOR When the sensor is read the ID pressure and temperature will be displayed 3 2 3 RECORD TIRE DATA In addition to displaying the current pressure and temperature of a sensor the 360SLT2 can also record tire data After pressing the Record Tire Data button on the Read Data Menu two axles are shown An asset...

Страница 11: ... This data can be exported or reviewed in the Saved Files menu which is outlined in the following section 3 3 SAVED FILES Clicking on the Saved Files button will bring up a list with all of the assets that have been stored on the tablet A red tire indicates an alarm condition has been recorded A blue dot indicates that all tires on the asset are at correct pressures and temperatures Pressing the E...

Страница 12: ... software The Tablet Settings button will navigate to Android settings such as Wi Fi Bluetooth Display and Notification settings Lastly the Email button will guide a user through setting up an email account on the tablet This can be used to email saved data and photos off the tablet 3 5 YARDCHECK360 WEB PORTAL If YardCheck360 hardware is being used the YardCheck360 web portal can be accessed by th...

Страница 13: ...360SLT2 SMARTLINKTM TPMS Tablet User Manual v1 Doran Mfg LLC 2851 Massachusetts Ave Cincinnati OH 45225 866 816 7233 Doranmfg com 13 ...

Страница 14: ...it Why doesn t my tablet turn on Press and hold the power button for a few seconds until the Doran logo appears on a white screen If the tablet does not power on check if the battery needs charged Why can t I see the sensor ID in the data read from the transceiver The sensor ID is not included in the data transmission from the transceiver to the tablet The sensor ID is only available if the data i...

Страница 15: ...tion Wi Fi 2 4G 2 4G Bluetooth 2 4G 2 4G RF 434 1MHz 434 1MHz LF 125kHz 125kHz Tablet Information OS Android 7 1 2 Storage 8GB Camera 5 0MP Touch panel Capacitive Display 7 IPS Screen resolution 1280x800 Power Adapter 100 240V Battery 5000mAh Power consumption 8W Working Temperature 0 55 Storage Temperature 20 60 Dimensions 250Lx130Wx23H mm Weight 0 56 kg Connection USB Type C USB OTG Micro SD car...

Страница 16: ...s subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation FCC Caution Any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate this equipment RF exposure warning This equipmen...

Страница 17: ...E This Limited Warranty does not apply to any claims arising No other remedy shall be available therefore f the purchase price or the refund o repair or replacement of such defective product LLC to be defective within such period shall at the sole option of DORAN MFG LLC be the any subsequent users The exclusive remedy for any product determined by DORAN MFG ed transferred or conveyed to user and ...

Страница 18: ...n and shipping of the returned product A copy of the sales slip from the point of purchase must accompany the returned product APPLICABLE LAW The internal laws of the State of Ohio U S A shall govern this Limited Warranty and the exclusive venue for any dispute in connection with the purchase or use of the product shall be the state and federal courts of general jurisdiction located in Hamilton Co...

Страница 19: ...t User Manual v1 Doran Mfg LLC 2851 Massachusetts Ave Cincinnati OH 45225 866 816 7233 Doranmfg com DORAN MANUFACTURING CO LLC 2851 Massachusetts Avenue Cincinnati OH 45225 Tel 866 816 7233 Fax 513 681 5604 Website www Doranmfg com ...

Отзывы: