Doran SCC-AM-00 Скачать руководство пользователя страница 14

 

13 

These two (2) timer modes are independently enabled.  The Doran 
Sleeping Child Check (SCC-AM) may be ordered with options already 
enabled.   Or users may enable timers themselves; however some 
disassembly may be required to properly access the programming 
jumpers.  

If damage occurs from this procedure, Doran will not 

warrant the product.

 

 

Selecting Timer Options 

 

Jumper 

   JP1*   Open/cut JP1 for Horn ALARM to be triggered 1 Minute after Ignition Off 
   JP2*   Open/cut JP2 will ARM module after 10 continuous minutes with Ignition Input On.  

The module may be ARMED either way when P6 is used in this mode. 

 
*Note: For the 24 volt model, pcb versions before 1.11, the instructions for JP1 and JP2 are 
reversed due to mislabeling.  Pictured is the 12 volt model. 

 

 
 
 
 
 
 
 
 
 
 
 
 
 

Open JP1 for 1 Min. after stop 
ALARM timer. 
Open JP2 for 10 Min. ARM 
timer. 

Содержание SCC-AM-00

Страница 1: ...CHECK Model SCC AM 00 01 and Model SCC AM 24V INSTALLATION AND OPERATION MANUAL Doran Manufacturing LLC 2851 Massachusetts Ave Cincinnati Ohio 45225 866 816 7233 TEL 513 681 5604 FAX www doranmfg com...

Страница 2: ...structions find online at www doranmfg com Electric drill and 5 8 drill bit Test Light Probe 16 or 14 gauge wire Automotive GXL SLX or equivalent Insulated female quick connectors for 250 blades Wire...

Страница 3: ...at Rear of Bus GND SCC AM DOME LIGHT OUTPUT IS FUSED FOR 10 AMPS MAXIMUM A RELAY WILL BE REQUIRED FOR CIRCUITS GREATER THAN 10 AMPS BAT P1 GND ACCESSORY POWER V battery LEFT OR RIGHT RED WARNING SIGNA...

Страница 4: ...attery V battery ACCESSORY POWER IGNITION V battery Option 3 CONVERSION VANS MINIBUSES DOME LIGHTS SCC AM DOME LIGHT OUTPUT IS FUSED FOR 10 AMPS MAXIMUM A RELAY WILL BE REQUIRED FOR CIRCUITS GREATER T...

Страница 5: ...m the battery The fuses on the module protect the relays and the load and also limit current through BAT and BAT But if both fuses are in the NEG position then the sum of load currents flows through P...

Страница 6: ...ion the SCC system will require deactivation at the end of the trip See Timer Options for another alternative For testing and trouble shooting when the SCC is in ARMed state the Yellow LED is illumina...

Страница 7: ...P1 Battery Make a connection from P1 Bat terminal on the SCC to constant Pos battery voltage With the ignition turned OFF use a test probe to locate a wire with constant positive voltage GROUND P2 Bat...

Страница 8: ...nvenient place to connect to the switch may be at the flasher unit which uses the door switch Frt_DOOR is expecting a ground when the door begins to open Frt_DOOR pin P7 may be used if Bat V is presen...

Страница 9: ...ease the current capacity See Figure 2 To use this feature you will need to determine how the manual switch activates these lights Find the wire going to the lights from the switch With a test light o...

Страница 10: ...SION VANS MINI BUSES W 0 WARNING FLASHERS Use ignition accessory or brake light input at the ARM terminal P6 This usually means the system will need to be reset after any startup Where driver usually...

Страница 11: ...Start the school bus Make sure all the doors are closed 2 Activate the Red warning light flashers and open the door The YELLOW LED will light on the circuit board to show the system is armed 3 Turn o...

Страница 12: ...quired to be installed please follow the instructions below COMMON COM TERMINAL BRACKET MINATURE SWITCH NORMALLY CLOSED NC TERMINAL ROLLER ARM Figure 5 SCC AM SW 00 Switch Remove the panel above the a...

Страница 13: ...Battery Voltage signal on the ARM terminal P6 if it is connected Some states require an additional way to ARM the module for field trips shuttles and other group trips when the warning lights may not...

Страница 14: ...ill not warrant the product Selecting Timer Options Jumper JP1 Open cut JP1 for Horn ALARM to be triggered 1 Minute after Ignition Off JP2 Open cut JP2 will ARM module after 10 continuous minutes with...

Страница 15: ...en the power is off to the device sometimes the flasher unit will cause this In this case the SCC door input must be isolated from the other device s or a separate door switch or contact must be used...

Отзывы: