OP000530
4-91
Inspection, Maintenance and Adjustment
VENTING AND PRIMING
HYDRAULIC SYSTEM
Main System Pump
NOTE:
If pump is run without sufficient oil in the main
hydraulic pump, damage can occur. Always vent
pump of air after draining hydraulic system.
1.
With the engine stopped, remove vent plug (Figure 169) to
see if any oil is present.
2.
If oil is not present, fill pump with oil through port (Figure
169).
3.
Install vent plug (Figure 169) first.
4.
Start engine and run it for several minutes at low idle
engine speed. This will pressurize the hydraulic oil tank
and system.
5.
Slowly loosen vent plug (Figure 169) several turns, until
hydraulic oil flows out of plug. This shows that air has been
released.
6.
Tighten the plug (Figure 169).
Hydraulic Cylinders
1.
Run engine at low idle. Extend and retract each cylinder to
within 100 mm (4 in) of fully stroking it 4 - 5 times.
2.
Operate fully extend and retract each cylinder 3- 4 times.
3.
Repeat procedure until cylinders extend and retract
smoothly.
FG003414
Figure 169
IMPORTANT
If cylinders are operated in high idle after the hydraulic
system has been drained or the cylinder has been rebuilt,
damage to piston packing and seals may occur. Always
vent air from cylinders at low idle and at a slow speed.