OP000530
Inspection, Maintenance and Adjustment
4-56
Hydraulic Oil Exchange and Suction
Strainer Cleaning
NOTE:
Based on the type of excavating being completed,
the working conditions (extremely hot or dusty) and
the extra front end attachments being used (hydraulic
breaker, etc.), the hydraulic fluid will need to be
changed more frequently.
1.
Position the machine on firm, level ground. Swing upper
structure perpendicular (90°) to wheels. Lower boom and
position bucket on ground as shown in Figure 105.
2.
Set safety lever and stand on "LOCK" position.
3.
Shut down engine.
4.
Release pressurized air from hydraulic tank by rotating
breather cap (1, Figure 108).
Figure 104
ARO1760L
WARNING!
The hydraulic oil will be hot after normal machine
operation. Allow the system to cool before attempting to
service any of the hydraulic components.
The hydraulic tank is pressurized. Loosen the breather cap
to allow the pressurized air to vent. After the pressure has
been released, it is safe to remove either the fill cap or
service covers.
IMPORTANT
Make sure to clean any dirt or water from the top of the
hydraulic tank, especially around the fill port and filter
ports.
Hydraulic oil change interval is 2,000 hours, only when
DOOSAN
Genuine Oil is used. If another brand of oil is
used, guaranteed change interval is 1,000 hours.
FG008608
Figure 105
Содержание DX190W
Страница 2: ......
Страница 71: ...OP000528 2 3 Operating Controls ...
Страница 128: ...OP000528 Operating Controls 2 60 CD Player Optional AST DIR FG000109 Figure 135 ...
Страница 196: ......
Страница 292: ...OP000530 Inspection Maintenance and Adjustment 4 96 ...
Страница 304: ...OP000440 6 8 Troubleshooting ...